8C-04

Daikin Altherma 4 H F 8C-04: Undercooling of the main zone water circuit

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Air-to-water heat pump outdoor unit next to a house
Mueller felixCC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

8C-04 means “Undercooling of the main zone water circuit” on the scoped Altherma 4 H F family. Daikin records this trigger: The minimum temperature in the main zone is below the undercooling temperature threshold. Effect: Pump will stop running. The table marks the reset as automatic.

Safety first

Stop and check this first

  • Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

Safe checks you can perform

  • Preserve the diagnostic state
  • Let the automatic reset logic decide
  • Keep the check outside the casing

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measured handoff for 8C-04

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured handoff for 8C-04

    What they doGive the technician 8C-04, both model numbers, the source trigger “The minimum temperature in the main zone is below the undercooling temperature threshold”, the effect “Pump will stop running”, reset result and recurrence conditions. They should follow Daikin's exact controller decision branch and compare live measurements with the service values before replacing parts.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Preserve the diagnostic state

    No special tools

    Photograph 8C-04 and the complete display. Record both unit model numbers, operating mode, requested temperatures, weather, system pressure shown to the user and the moment the code appeared.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  2. Let the automatic reset logic decide

    No special tools

    Daikin marks this code as automatic reset. Do not cycle breakers or force repeated acknowledgements. Record whether the controller clears it and the exact operating state in which it returns.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  3. Keep the check outside the casing

    No special tools

    Use only normal controls and user-accessible observations. Do not remove covers, bypass a safety device or replace a part from the code alone.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Heat pumps
Brand
Daikin
Product type
Air-to-water heat pump

Known code variants

  • Altherma 4 H F 8C-04
  • code erreur Daikin Altherma 8C-04
  • codice 8C-04 pompa di calore Daikin
  • código 8C-04 bomba de calor Daikin
  • Daikin 8C-04
  • Daikin Altherma error 8C-04
  • Daikin Altherma Fehler 8C-04
  • Daikin heat pump code 8C-04
  • Daikin Wärmepumpe Fehlercode 8C-04
  • défaut 8C-04 pompe à chaleur Daikin
  • error Daikin Altherma 8C-04
  • errore Daikin Altherma 8C-04

What it means

In guide 4P773391-1C (2026.02), Daikin assigns 8C-04 to “Undercooling of the main zone water circuit”. The documented trigger is “The minimum temperature in the main zone is below the undercooling temperature threshold” and the operating effect is “Pump will stop running”. This is a precise controller decision for Daikin Altherma 4 H F — EPSK(S)04~14A + EPVX07~14S18+23A; it does not by itself prove which component failed.

Warnings and stop conditions

  • Highsource verified

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Symptoms and causes

Probable causes · in order

  • What the controller establishedConfirmed

    Daikin's table defines the condition as “Undercooling of the main zone water circuit” and gives this exact trigger: The minimum temperature in the main zone is below the undercooling temperature threshold.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  • What the unit does nextConfirmed

    Documented effect: Pump will stop running. Reset classification: Automatic. A cleared display is not proof of repair.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Virtual technician

Does 8C-04 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.