EC00

Daikin Altherma 4 H F EC-00: Abnormal increase tank temperature

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Air-to-water heat pump outdoor unit next to a house
Mueller felixCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

High

Quick answer

EC-00 means “Abnormal increase tank temperature” on the scoped Altherma 4 H F family. Daikin records this trigger: Temperature of the tank is abnormally increasing. There is a potential problem with one of the heat sources connected to the tank. Effect: Domestic hot water operation will stop. The table marks the reset as manual.

Safety first

Stop and check this first

  • Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

Safe checks you can perform

  • Preserve the diagnostic state
  • Use the displayed reset path once
  • Do not substitute a sensor diagnosis

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measured handoff for EC-00

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured handoff for EC-00

    What they doGive the technician EC-00, both model numbers, the source trigger “Temperature of the tank is abnormally increasing. There is a potential problem with one of the heat sources connected to the tank”, the effect “Domestic hot water operation will stop”, reset result and recurrence conditions. They should follow Daikin's sensor and measured value branch and compare live measurements with the service values before replacing parts.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Preserve the diagnostic state

    No special tools

    Photograph EC-00 and the complete display. Record both unit model numbers, operating mode, requested temperatures, weather, system pressure shown to the user and the moment the code appeared.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  2. Use the displayed reset path once

    No special tools

    Daikin marks this code as manual reset. Only when the installation is safe, follow the reset instruction shown by the user interface or the exact user manual once. Do not enter maintenance mode; recurrence ends user troubleshooting.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  3. Do not substitute a sensor diagnosis

    No special tools

    Note the displayed temperatures and whether they are stable or implausible. Do not unplug, bridge, heat, cool or resistance-test any sensor and do not open either unit.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Heat pumps
Brand
Daikin
Product type
Air-to-water heat pump

Known code variants

  • Altherma 4 H F EC-00
  • code erreur Daikin Altherma EC-00
  • codice EC-00 pompa di calore Daikin
  • código EC-00 bomba de calor Daikin
  • Daikin Altherma error EC-00
  • Daikin Altherma Fehler EC-00
  • Daikin EC-00
  • Daikin heat pump code EC-00
  • Daikin Wärmepumpe Fehlercode EC-00
  • défaut EC-00 pompe à chaleur Daikin
  • error Daikin Altherma EC-00
  • errore Daikin Altherma EC-00

What it means

In guide 4P773391-1C (2026.02), Daikin assigns EC-00 to “Abnormal increase tank temperature”. The documented trigger is “Temperature of the tank is abnormally increasing. There is a potential problem with one of the heat sources connected to the tank” and the operating effect is “Domestic hot water operation will stop”. This is a precise controller decision for Daikin Altherma 4 H F — EPSK(S)04~14A + EPVX07~14S18+23A; it does not by itself prove which component failed.

Warnings and stop conditions

  • Highsource verified

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Symptoms and causes

Probable causes · in order

  • What the controller establishedConfirmed

    Daikin's table defines the condition as “Abnormal increase tank temperature” and gives this exact trigger: Temperature of the tank is abnormally increasing. There is a potential problem with one of the heat sources connected to the tank.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  • What the unit does nextConfirmed

    Documented effect: Domestic hot water operation will stop. Reset classification: Manual. A cleared display is not proof of repair.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Virtual technician

Does EC00 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1Creviewed 2026-08-23 · verified