HJ10
Daikin Altherma 4 H F HJ-10: Water pressure sensor abnormality

Risk level
Medium
Proceed carefully and stop if the check is unclear.
Urgency
High
Quick answer
HJ-10 means “Water pressure sensor abnormality” on the scoped Altherma 4 H F family. Daikin records this trigger: Water pressure input is out of range. Effect: Unit will continue operation. The table marks the reset as automatic.
Safety first
Stop and check this first
- Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Safe checks you can perform
- Preserve the diagnostic state
- Let the automatic reset logic decide
- Check only user-visible water-circuit evidence
Leave these tasks to a qualified professional
- Do not attempt this professional task: Measured handoff for HJ-10
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Measured handoff for HJ-10
What they doGive the technician HJ-10, both model numbers, the source trigger “Water pressure input is out of range”, the effect “Unit will continue operation”, reset result and recurrence conditions. They should follow Daikin's water flow and pump branch and compare live measurements with the service values before replacing parts.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Preserve the diagnostic state
Photograph HJ-10 and the complete display. Record both unit model numbers, operating mode, requested temperatures, weather, system pressure shown to the user and the moment the code appeared.
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Let the automatic reset logic decide
Daikin marks this code as automatic reset. Do not cycle breakers or force repeated acknowledgements. Record whether the controller clears it and the exact operating state in which it returns.
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Check only user-visible water-circuit evidence
If the user manual permits it, read the displayed system pressure, confirm no user-accessible valve was accidentally closed and look for a visible leak. Do not fill, bleed, clean strainers or measure flow unless the exact user manual assigns that task to the user.
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Heat pumps
- Brand
- Daikin
- Product type
- Air-to-water heat pump
Known code variants
- Altherma 4 H F HJ-10
- code erreur Daikin Altherma HJ-10
- codice HJ-10 pompa di calore Daikin
- código HJ-10 bomba de calor Daikin
- Daikin Altherma error HJ-10
- Daikin Altherma Fehler HJ-10
- Daikin heat pump code HJ-10
- Daikin HJ-10
- Daikin Wärmepumpe Fehlercode HJ-10
- défaut HJ-10 pompe à chaleur Daikin
- error Daikin Altherma HJ-10
- errore Daikin Altherma HJ-10
What it means
In guide 4P773391-1C (2026.02), Daikin assigns HJ-10 to “Water pressure sensor abnormality”. The documented trigger is “Water pressure input is out of range” and the operating effect is “Unit will continue operation”. This is a precise controller decision for Daikin Altherma 4 H F — EPSK(S)04~14A + EPVX07~14S18+23A; it does not by itself prove which component failed.
Warnings and stop conditions
- Highsource verified
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Symptoms and causes
Probable causes · in order
- What the controller establishedConfirmed
Daikin's table defines the condition as “Water pressure sensor abnormality” and gives this exact trigger: Water pressure input is out of range.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
- What the unit does nextConfirmed
Documented effect: Unit will continue operation. Reset classification: Automatic. A cleared display is not proof of repair.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Virtual technician
Does HJ10 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.