U2-35

Daikin Altherma 4 H F U2-35: Supply voltage error

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Air-to-water heat pump outdoor unit next to a house
Mueller felixCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

High

Quick answer

U2-35 means “Supply voltage error” on the scoped Altherma 4 H F family. Daikin records this trigger: AC voltage sensor error. Effect: Heat pump will stop operating. The table marks the reset as manual.

Safety first

Stop and check this first

  • Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

Safe checks you can perform

  • Preserve the diagnostic state
  • Use the displayed reset path once
  • Do not substitute a sensor diagnosis

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measured handoff for U2-35

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured handoff for U2-35

    What they doGive the technician U2-35, both model numbers, the source trigger “AC voltage sensor error”, the effect “Heat pump will stop operating”, reset result and recurrence conditions. They should follow Daikin's sensor and measured value branch and compare live measurements with the service values before replacing parts.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Preserve the diagnostic state

    No special tools

    Photograph U2-35 and the complete display. Record both unit model numbers, operating mode, requested temperatures, weather, system pressure shown to the user and the moment the code appeared.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  2. Use the displayed reset path once

    No special tools

    Daikin marks this code as manual reset. Only when the installation is safe, follow the reset instruction shown by the user interface or the exact user manual once. Do not enter maintenance mode; recurrence ends user troubleshooting.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  3. Do not substitute a sensor diagnosis

    No special tools

    Note the displayed temperatures and whether they are stable or implausible. Do not unplug, bridge, heat, cool or resistance-test any sensor and do not open either unit.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Heat pumps
Brand
Daikin
Product type
Air-to-water heat pump

Known code variants

  • Altherma 4 H F U2-35
  • code erreur Daikin Altherma U2-35
  • codice U2-35 pompa di calore Daikin
  • código U2-35 bomba de calor Daikin
  • Daikin Altherma error U2-35
  • Daikin Altherma Fehler U2-35
  • Daikin heat pump code U2-35
  • Daikin U2-35
  • Daikin Wärmepumpe Fehlercode U2-35
  • défaut U2-35 pompe à chaleur Daikin
  • error Daikin Altherma U2-35
  • errore Daikin Altherma U2-35

What it means

In guide 4P773391-1C (2026.02), Daikin assigns U2-35 to “Supply voltage error”. The documented trigger is “AC voltage sensor error” and the operating effect is “Heat pump will stop operating”. This is a precise controller decision for Daikin Altherma 4 H F — EPSK(S)04~14A + EPVX07~14S18+23A; it does not by itself prove which component failed.

Warnings and stop conditions

  • Highsource verified

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Symptoms and causes

Probable causes · in order

  • What the controller establishedConfirmed

    Daikin's table defines the condition as “Supply voltage error” and gives this exact trigger: AC voltage sensor error.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  • What the unit does nextConfirmed

    Documented effect: Heat pump will stop operating. Reset classification: Manual. A cleared display is not proof of repair.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C