- Heat pumps
- Air-to-water heat pump
U2-44
Daikin Altherma 4 H F U2-44: Supply voltage error

Risk level
High
Professional inspection is recommended.
Urgency
High
Quick answer
U2-44 means “Supply voltage error” on the scoped Altherma 4 H F family. Daikin records this trigger: Undervoltage during operation. Effect: Heat pump will stop operating. The table marks the reset as manual.
Safety first
Stop and check this first
- Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Safe checks you can perform
- Preserve the diagnostic state
- Use the displayed reset path once
- Isolate abnormal electrical symptoms
Leave these tasks to a qualified professional
- Do not attempt this professional task: Measured handoff for U2-44
What a technician must be able to justify
A technician is coming
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Measured handoff for U2-44
What they doGive the technician U2-44, both model numbers, the source trigger “Undervoltage during operation”, the effect “Heat pump will stop operating”, reset result and recurrence conditions. They should follow Daikin's power and electrical protection branch and compare live measurements with the service values before replacing parts.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Checks and evidence, step by step
Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
- 1
Preserve the diagnostic state
No special tools
Procedure
Photograph U2-44 and the complete display. Record both unit model numbers, operating mode, requested temperatures, weather, system pressure shown to the user and the moment the code appeared.
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
- 2
Use the displayed reset path once
No special tools
Procedure
Daikin marks this code as manual reset. Only when the installation is safe, follow the reset instruction shown by the user interface or the exact user manual once. Do not enter maintenance mode; recurrence ends user troubleshooting.
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
- 3
Isolate abnormal electrical symptoms
No special tools
Procedure
Leave the system off after burning smell, heat, noise, sparking or repeated protective trips. Do not open electrical panels, test terminals or repeatedly re-energize the unit.
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Heat pumps
- Brand
- Daikin
- Product type
- Air-to-water heat pump
Known code variants
- Altherma 4 H F U2-44
- code erreur Daikin Altherma U2-44
- codice U2-44 pompa di calore Daikin
- código U2-44 bomba de calor Daikin
- Daikin Altherma error U2-44
- Daikin Altherma Fehler U2-44
- Daikin heat pump code U2-44
- Daikin U2-44
- Daikin Wärmepumpe Fehlercode U2-44
- défaut U2-44 pompe à chaleur Daikin
- error Daikin Altherma U2-44
- errore Daikin Altherma U2-44
What it means
In guide 4P773391-1C (2026.02), Daikin assigns U2-44 to “Supply voltage error”. The documented trigger is “Undervoltage during operation” and the operating effect is “Heat pump will stop operating”. This is a precise controller decision for Daikin Altherma 4 H F — EPSK(S)04~14A + EPVX07~14S18+23A; it does not by itself prove which component failed.
Warnings and stop conditions
- Highsource verified
Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Symptoms and causes
Probable causes · in order
- What the controller establishedConfirmed
Daikin's table defines the condition as “Supply voltage error” and gives this exact trigger: Undervoltage during operation.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
- What the unit does nextConfirmed
Documented effect: Heat pump will stop operating. Reset classification: Manual. A cleared display is not proof of repair.
Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Virtual technician
Does U2-44 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C
Daikin Europe N.V. · 2026 · official_doc
Was this entry useful?