  • Air-to-water heat pump

UH18

Daikin Altherma 4 H F UH-18: Outdoor unit locked (R290)

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Air-to-water heat pump outdoor unit next to a house
Mueller felixCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

Immediate

Quick answer

UH-18 means “Outdoor unit locked (R290)” on the scoped Altherma 4 H F family. Daikin records this trigger: Outdoor unit locked state. Effect: Heat pump will stop operating. The table marks the reset as manual.

Safety first

Stop and check this first

  • Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

Safe checks you can perform

  • Preserve the diagnostic state
  • Use the displayed reset path once
  • Treat the sealed R290 system as professional-only

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measured handoff for UH-18

What a technician must be able to justify

A technician is coming

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured handoff for UH-18

    What they doGive the technician UH-18, both model numbers, the source trigger “Outdoor unit locked state”, the effect “Heat pump will stop operating”, reset result and recurrence conditions. They should follow Daikin's R290 refrigerant and compressor branch and compare live measurements with the service values before replacing parts.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Checks and evidence, step by step

Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. 1

    Preserve the diagnostic state

    No special tools

    Procedure

    Photograph UH-18 and the complete display. Record both unit model numbers, operating mode, requested temperatures, weather, system pressure shown to the user and the moment the code appeared.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  2. 2

    Use the displayed reset path once

    No special tools

    Procedure

    Daikin marks this code as manual reset. Only when the installation is safe, follow the reset instruction shown by the user interface or the exact user manual once. Do not enter maintenance mode; recurrence ends user troubleshooting.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  3. 3

    Treat the sealed R290 system as professional-only

    No special tools

    Procedure

    Keep flames and ignition sources away and do not loosen panels, valves or pipework. An R290, pressure, compressor or refrigerant-circuit decision requires a certified technician and the manufacturer procedure.

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Heat pumps
Brand
Daikin
Product type
Air-to-water heat pump

Known code variants

  • Altherma 4 H F UH-18
  • code erreur Daikin Altherma UH-18
  • codice UH-18 pompa di calore Daikin
  • código UH-18 bomba de calor Daikin
  • Daikin Altherma error UH-18
  • Daikin Altherma Fehler UH-18
  • Daikin heat pump code UH-18
  • Daikin UH-18
  • Daikin Wärmepumpe Fehlercode UH-18
  • défaut UH-18 pompe à chaleur Daikin
  • error Daikin Altherma UH-18
  • errore Daikin Altherma UH-18

What it means

In guide 4P773391-1C (2026.02), Daikin assigns UH-18 to “Outdoor unit locked (R290)”. The documented trigger is “Outdoor unit locked state” and the operating effect is “Heat pump will stop operating”. This is a precise controller decision for Daikin Altherma 4 H F — EPSK(S)04~14A + EPVX07~14S18+23A; it does not by itself prove which component failed.

Warnings and stop conditions

  • Criticalsource verified

    Stop and isolate the installation for smoke, burning smell, sparks, unusual heat, water near electrical parts, suspected refrigerant release or repeated protective trips. Do not open the R290 refrigerant circuit or live electrical compartments.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Symptoms and causes

Probable causes · in order

  • What the controller establishedConfirmed

    Daikin's table defines the condition as “Outdoor unit locked (R290)” and gives this exact trigger: Outdoor unit locked state.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

  • What the unit does nextConfirmed

    Documented effect: Heat pump will stop operating. Reset classification: Manual. A cleared display is not proof of repair.

    Evidence: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1C

Virtual technician

Does UH18 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Daikin Altherma 4 H F installer reference guide — 4PEN773391-1Creviewed 2026-08-23 · verified

Was this entry useful?