Independent technical referenceOfficial site
  • Heat pumps
  • Pool heat pump

ER06

Zodiac Er06 on pool heat pump: low pressure protection

Verified with sources1 sourceReviewed Oct 4, 2026
Technician coming? See the 2 steps they must show you
Pool heat pump with front fan and water hoses installed in a garden
Nenad StojkovicCC BY 2.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

Medium

Quick answer

On the Zodiac Z250, Er06 means the refrigerant circuit low pressure protection tripped. Switch the unit off, note when it appeared and call a refrigeration technician: every cause Zodiac lists is inside the R32 circuit.

Safety first

Stop and check this first

  • This heat pump uses R32, an A2L refrigerant that Zodiac describes as potentially flammable and which may have no smell. Do not open the unit or bring flames near it: only a qualified refrigeration technician.
  • Zodiac forbids releasing R32 into the atmosphere. Make sure the technician recovers the gas and puts the quantities in writing.

Safe checks you can perform

  • Logging the alert
  • Evaporator clean and unobstructed
  • Clearing the fault after 3 alerts

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measuring pressures and finding the leak
  • Do not attempt this professional task: Testing the low pressure switch and 4-way valve

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measuring pressures and finding the leak

    What they doAn F-gas certified technician measures R32 circuit pressures and, if gas is missing, locates the leak with a detector suitable for flammable refrigerants before recharging.

    They must show youthe measured pressures against the manufacturer figures and the leak point found.

    In writingthe leak repaired, gas recovered and added and the technician's certificate number.

  2. Testing the low pressure switch and 4-way valve

    What they doWith the unit isolated, the technician checks the low pressure switch connection and compares it with measured pressures; then tests 4-way valve switching.

    They must show youthe comparison between measured pressure and switch operation.

    In writingwhich component failed and the part number replaced.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Logging the alert

    No special tools

    Who:
    you, no tools.
    How:
    note the date, time, mode (heating or cooling) and whether it was cold outside when Er06 appeared. The manual gives an air operating range of -7 to 43 °C for this model.
    Result that matters:
    a record the technician can match with the pressures they measure.
    If it only appears in very cold weather or outside the air range:
    tell the technician, it changes the diagnosis.
    If it appears in normal temperatures:
    it strengthens the suspicion of a circuit problem.
    Evidence to keep:
    note with date, time, mode and approximate outdoor temperature.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

  2. Evaporator clean and unobstructed

    No special tools

    Who:
    you, with the power cut.
    How:
    look at the rear finned coil. If it is dirty, Zodiac says to clean it with a soft brush and a fresh water spray, no high pressure jet and without bending the fins, with the cable disconnected. Remove leaves or objects blocking the air inlet.
    Result that matters:
    clean fins and free air around the unit.
    If it was very dirty:
    Zodiac does not list it as an Er06 cause, but the technician needs a clean unit to measure properly.
    If it was clean:
    nothing changes; still do not open the unit.
    Evidence to keep:
    photo of the evaporator before and after.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

  3. Clearing the fault after 3 alerts

    No special tools

    Who:
    you, from the heat pump isolator, without opening it.
    How:
    if Er06 has appeared 3 times in 30 minutes, Zodiac says to unplug the unit to clear it. Wait one minute before restoring power, as the manual says.
    Result that matters:
    knowing whether the alert comes back quickly.
    If it returns soon:
    leave the unit off and call the technician.
    If it does not return for days:
    keep the log anyway; the cause may still be there.
    Evidence to keep:
    how long it took to return after the reset.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Heat pumps
Brand
Zodiac
Product type
Pool heat pump

Known code variants

  • bomba de calor Zodiac baja presión
  • E06
  • Er 06
  • Poolex 06
  • Poolex E06
  • Poolex error 06
  • Poolex Jetline Selection Fi 06
  • Poolex low pressure protection
  • Poolex protección baja presión
  • Zodiac Er06
  • Zodiac heat pump low pressure
  • Zodiac low pressure protection
  • Zodiac protección baja presión
  • Zodiac Z250 Er06

What it means

Er06 is the low pressure protection of the R32 refrigerant circuit. The low pressure switch stops the compressor when suction pressure drops too far. Zodiac gives three causes: insufficient refrigerant gas, a faulty 4-way valve and a low pressure switch that is disconnected or faulty. None can be seen from outside, and missing gas is only confirmed with gauges and by finding the leak. So the code alone does not prove a leak or a broken part. If it appears 3 times in 30 minutes, the unit must be unplugged to clear it.

Warnings and stop conditions

  • Highsource verified

    This heat pump uses R32, an A2L refrigerant that Zodiac describes as potentially flammable and which may have no smell. Do not open the unit or bring flames near it: only a qualified refrigeration technician.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

  • Mediumsource verified

    Zodiac forbids releasing R32 into the atmosphere. Make sure the technician recovers the gas and puts the quantities in writing.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

Symptoms and causes

Probable causes · in order

  • Insufficient refrigerant gasCommon

    The R32 charge is low, usually from a leak; it is told apart by measuring pressures and finding the leak, not just by recharging.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

  • Faulty 4-way valvePossible

    The valve that reverses the cycle does not switch properly and suction pressure drops; confirmed by testing its switching.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

  • Low pressure switch disconnected or faultyPossible

    The switch alarms without pressure really being low; confirmed by checking its connection and comparing with measured pressures.

    Evidence: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

Virtual technician

Does ER06 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

  1. 1

    Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)

    Zodiac Pool Care Europe (Fluidra) · 2023 · official_doc

Sources: Zodiac Z250 heat pump: instructions for installation and use (H0791500 Rev B)reviewed 2026-10-04 · verified

Was this entry useful?