E.02.35

Baxi E.02.35 on a gas boiler: safety device disconnected

Verified with sources1 sourceReviewed Oct 4, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

High

Quick answer

Baxi E.02.35 identifies a disconnected critical safety device. Save the complete code and arrange service: the installer must check communication and the devices at X9 without bypassing them.

Safety first

Stop and check this first

  • If you smell gas while investigating E.02.35, leave the home without operating switches or creating sparks; avoid flames and smoking, close the main gas valve if safe and call the gas emergency service from outside.
  • Do not bridge terminals to clear E.02.35: the safety function must remain intact while its communication fault is investigated.

Safe checks you can perform

  • Identify warning E.02.35
  • Prepare the installation history
  • Identify the safety circuit

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Identify the safety circuit
  • Do not attempt this professional task: Automatic detection and final verification

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Identify the safety circuit

    What they doA qualified gas boiler technician examines the devices connected to X9 and records which one has stopped communicating.

    They must show youthe affected device and the result of its inspection.

    In writingthe circuit identification and communication diagnosis.

  2. Automatic detection and final verification

    What they doThe technician runs the Baxi automatic detection procedure through AD and checks the outcome with the safety devices connected.

    They must show youthe detection outcome and final fault status.

    In writingthe procedure used and response from the safety device.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Identify warning E.02.35

    No special tools

    Who:
    you.
    How:
    Keep an image showing the whole E.02.35 code; distinguish it from a connection warning involving an ordinary accessory.
    What matters: Identifying a disconnected safety device requires the corresponding circuit to be checked before normal service is restored.
    If the warning persists:
    request service with the complete code and model.
    If it has cleared:
    retain the record and report any recurrence.
    Evidence to keep:
    dated photograph of E.02.35.

    Evidence: Baxi Neodens Lite 24 AF, 24/24 F y 28/28 F, manual de usuario, instalación y mantenimiento 7892434

  2. Prepare the installation history

    No special tools

    Who:
    you.
    How:
    Record whether this followed maintenance or connection of a device, and pass that history to the technician without unplugging anything.
    What matters: Installation history guides inspection but does not replace professional checks.
    If the warning persists:
    give this history to the qualified gas service company.
    If it has cleared:
    retain the record and report any recurrence.
    Evidence to keep:
    documents relating to Neodens Lite and E.02.35.

    Evidence: Baxi Neodens Lite 24 AF, 24/24 F y 28/28 F, manual de usuario, instalación y mantenimiento 7892434

  3. Identify the safety circuit

    Tools required

    Who:
    qualified gas installation technician.
    How:
    A qualified gas boiler technician examines the devices connected to X9 and records which one has stopped communicating.
    What matters: The diagnosis must explain E.02.35 using a verifiable check.
    If the warning persists:
    the professional completes diagnosis before signing off the repair.
    If it has cleared:
    retain the record and report any recurrence.
    Evidence to keep:
    the circuit identification and communication diagnosis.

    Internal inspection of Neodens Lite is restricted to qualified professionals; keep the casing closed.

    Evidence: Baxi Neodens Lite 24 AF, 24/24 F y 28/28 F, manual de usuario, instalación y mantenimiento 7892434

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Baxi
Product type
Gas boiler

Known code variants

  • Baxi E.02.35
  • E0235
  • Error E.02.35
  • Neodens Lite E.02.35

What it means

On the Neodens Lite, E.02.35 means a critical safety device is disconnected. Baxi places the checks under communication failure and directs the installer to automatic detection using parameter AD and the devices connected to X9. The message alone does not establish which component failed and does not authorise bridging a safety connection.

Warnings and stop conditions

  • Criticaleditorial warning

    If you smell gas while investigating E.02.35, leave the home without operating switches or creating sparks; avoid flames and smoking, close the main gas valve if safe and call the gas emergency service from outside.

    Evidence: Baxi Neodens Lite 24 AF, 24/24 F y 28/28 F, manual de usuario, instalación y mantenimiento 7892434

  • Highsource verified

    Do not bridge terminals to clear E.02.35: the safety function must remain intact while its communication fault is investigated.

    Evidence: Baxi Neodens Lite 24 AF, 24/24 F y 28/28 F, manual de usuario, instalación y mantenimiento 7892434

Symptoms and causes

Probable causes · in order

  • Safety device communication interruptedPossible

    The table links this fault to communication with a critical device and calls for checking the items connected to X9 and their detection.

    Evidence: Baxi Neodens Lite 24 AF, 24/24 F y 28/28 F, manual de usuario, instalación y mantenimiento 7892434

Virtual technician

Does E.02.35 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Baxi Neodens Lite 24 AF, 24/24 F y 28/28 F, manual de usuario, instalación y mantenimiento 7892434reviewed 2026-10-04 · verified