Independent technical referenceOfficial site
  • Boilers
  • Gas boiler

E130

Baxi E130 on a gas boiler: flue NTC sensor overheat

Verified with sources1 sourceReviewed Oct 4, 2026
Technician coming? See the 3 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

High

Quick answer

Baxi E130 means the flue NTC sensor has detected overheating. Check the flue terminal from outside, reset once by holding reset for at least 2 seconds and, if it returns, call the service centre. If you smell combustion fumes, switch off and ventilate.

Safety first

Stop and check this first

  • If you smell combustion fumes: Baxi says to switch the boiler off, ventilate by opening doors and windows and call the service centre. Carbon monoxide has no smell; if anyone has a headache, dizziness or nausea near the boiler, get outside and seek medical help.
  • If you smell gas: Baxi says to switch the boiler off, not to operate any electrical device or switch on lights, to put out any flame and open the windows. Then leave the home and call your gas distributor's emergency line and the service centre from outside.

Safe checks you can perform

  • Combustion smell and flue terminal
  • Pressure on the gauge
  • One reset with the reset key
  • Combustion check by the technician

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Flue sensor reading
  • Do not attempt this professional task: Combustion analysis
  • Do not attempt this professional task: Heat exchanger and flue check

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Flue sensor reading

    What they doThe technician compares the flue temperature in item 07 with an independent measurement at the flue test point.

    They must show youboth temperatures.

    In writingthe sensor's condition and whether it was replaced.

  2. Combustion analysis

    What they doThe technician measures CO2, CO and flue temperature with an analyser and compares them with the maker's values.

    They must show youthe analyser printout.

    In writingthe values and what was adjusted.

  3. Heat exchanger and flue check

    What they doThe technician checks the primary heat exchanger and the flue duct.

    They must show youthe condition of both.

    In writingthe cleaning or repair done.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Combustion smell and flue terminal

    No special tools

    Who:
    you.
    How:
    notice any smell of burnt gases and look at the flue terminal from the ground, without touching it.
    Result that matters:
    whether there is a smell or the terminal is covered.
    If there is a smell:
    switch the boiler off, ventilate and call the service centre.
    If the terminal is covered:
    do not reset; call the service centre.
    Evidence to keep:
    photos of the terminal and a note of the time.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

  2. Pressure on the gauge

    No special tools

    Who:
    you.
    How:
    with the system cold, check the gauge reads 1 to 1.5 bar, as Baxi asks.
    Result that matters:
    whether pressure is correct.
    If it is low:
    top up slowly with the filling tap and bleed the radiators, as Baxi describes.
    If it is correct:
    lack of water does not explain 130.
    Evidence to keep:
    a photo of the gauge.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

  3. One reset with the reset key

    No special tools

    Who:
    you.
    How:
    hold the reset key for at least 2 seconds, as Baxi says for 130. Baxi allows 5 consecutive resets and then a 15 minute wait: do one.
    Result that matters:
    whether the boiler heats again without the code.
    If it works:
    note the date; if it repeats, call the service centre.
    If 130 returns:
    do not keep trying; call the service centre.
    Evidence to keep:
    a photo of the display and a note of each reset.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

  4. Combustion check by the technician

    Tools required

    Who:
    authorised gas technician.
    How:
    checks the flue sensor, the heat exchanger, the flue and combustion with an analyser.
    Result that matters:
    why flue gases are hot.
    If the sensor fails:
    it is replaced.
    If the sensor reads correctly:
    the cause of overheating is corrected.
    Evidence to keep:
    a report with readings and what was corrected.

    Baxi says to call the authorised service centre: opening the boiler or touching the gas line or flue is not the user's job.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Baxi
Product type
Gas boiler

Known code variants

  • 130
  • Baxi 130
  • Baxi E 130
  • Error 130 Baxi
  • Platinum Compact 130

What it means

On the Platinum Compact ECO, code 130 is the flue NTC sensor tripping on overheat, and Baxi allows a reset by holding the key for at least 2 seconds. The sensor measures combustion gas temperature, which you can see in the information menu (item 07). Flue gases that are too hot mean heat is not passing properly to the water or combustion is not normal. The code does not say the cause or whether the sensor itself fails.

Warnings and stop conditions

  • Higheditorial warning

    If you smell combustion fumes: Baxi says to switch the boiler off, ventilate by opening doors and windows and call the service centre. Carbon monoxide has no smell; if anyone has a headache, dizziness or nausea near the boiler, get outside and seek medical help.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

  • Criticaleditorial warning

    If you smell gas: Baxi says to switch the boiler off, not to operate any electrical device or switch on lights, to put out any flame and open the windows. Then leave the home and call your gas distributor's emergency line and the service centre from outside.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

Symptoms and causes

Probable causes · in order

  • Heat not passing well to the waterPossible

    If 130 appears after heating for a while and pressure is low or there is air, the heat exchanger gives off less heat and flue gases leave hotter.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

  • Abnormal combustion or dischargePossible

    If the terminal is covered or there is a combustion smell, flue discharge or combustion is not normal; the technician checks it with an analyser.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

  • Faulty flue sensorLess common

    If item 07 shows an absurd temperature with the boiler cold, it points to the sensor or its connection.

    Evidence: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuario

Virtual technician

Does E130 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Baxi Platinum Compact ECO, instrucciones de funcionamiento y mantenimiento para el usuarioreviewed 2026-10-04 · verified

Was this entry useful?