Immergas 31 on a gas boiler: no communication with the remote

Verified with sources2 sourcesReviewed Oct 4, 2026
Technician coming? See the 3 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

Immergas 31 means the boiler has lost communication with the remote control. Unplug the boiler and plug it back in, as Immergas says; if it still does not detect the remote, the boiler runs from its own panel.

Safety first

Stop and check this first

  • If you smell gas: Immergas says to close the meter or main gas tap and, if you can, the boiler's gas tap, open doors and windows, use no naked flames, do not smoke and do not touch switches, sockets, doorbells or phones. Leave the home and call your gas distributor's emergency number from the street.
  • If the boiler does not detect the remote, the Victrix Omnia V2 stays in summer mode and gives no heating. If the home is cold and there are elderly people or babies, call the technician promptly.

Safe checks you can perform

  • Switching the power off and on
  • Boiler mode and remote message
  • Recent changes to the remote or thermostat
  • Remote terminals and wiring check by the technician

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Terminal connection
  • Do not attempt this professional task: Remote compatibility
  • Do not attempt this professional task: Separate line for the remote

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Terminal connection

    What they doChecks that the remote is connected to terminals 41 and 44/40 with the X40 jumper removed, as Immergas specifies for the CARV2.

    They must show youthe terminals checked.

    In writingwhat was found and corrected.

  2. Remote compatibility

    What they doConfirms that only one remote control is connected and that it is compatible with the boiler; an On/Off thermostat must have a clean, volt-free contact.

    They must show youthe remote model connected.

    In writingwhether the remote is compatible.

  3. Separate line for the remote

    What they doChecks that the remote cable runs on a separate line, as Immergas requires when a remote or programmable thermostat is used.

    They must show youthe cable route.

    In writingwhether the installation complies.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Switching the power off and on

    No special tools

    Who:
    you.
    How:
    switch the boiler off at the external main switch or unplug it, then restore the power, as Immergas says for 31.
    Result that matters:
    whether the boiler detects the remote after restarting.
    If the remote works again:
    note the time; it was a one-off dropout.
    If the boiler does not detect the remote:
    it runs from its panel; go to the next check.
    Evidence to keep:
    a photo of the display before and after.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA) · Immergas Victrix Superior 26-35, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047096SPA)

  2. Boiler mode and remote message

    No special tools

    Who:
    you.
    How:
    look at the boiler display and the CARV2 display. Immergas says that if the boiler is put into off mode, the CARV2 shows the connection error ERR>CM.
    Result that matters:
    whether the boiler was in off mode or there really is a communication fault.
    If the boiler was off:
    switch it on with its button and see whether the remote comes back.
    If the boiler is on and shows 31:
    the communication fault remains; tell the technician.
    Evidence to keep:
    a photo of both displays.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA)

  3. Recent changes to the remote or thermostat

    No special tools

    Who:
    you.
    How:
    think whether a remote, thermostat or programmable thermostat was recently changed or added, and note its make and model without removing it.
    Result that matters:
    whether there is more than one remote or one that may not be compatible.
    If something was changed recently:
    tell the technician; Immergas allows only one remote control.
    If nothing has changed:
    a communication dropout or the terminals become more likely.
    Evidence to keep:
    a photo of the remote and its label.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA)

  4. Remote terminals and wiring check by the technician

    Tools required

    Who:
    technician from an authorised company.
    How:
    with the boiler isolated, checks the remote connection at terminals 41 and 44/40, the X40 jumper and the wiring to the remote.
    Result that matters:
    whether the connection is correct and the remote is compatible.
    If a terminal is loose or wrongly connected:
    corrects it and tests the communication.
    If the connection is fine:
    checks the remote itself against its manual.
    Evidence to keep:
    a job sheet with what was checked and the test result.

    Immergas says to cut the power before touching the remote connections and tells the user not to open or tamper with the appliance.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA) · Immergas Victrix Superior 26-35, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047096SPA)

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Immergas
Product type
Gas boiler

Known code variants

  • E31
  • Error 31 Immergas
  • Immergas E31
  • Victrix 31
  • Victrix E31

What it means

Code 31 is loss of communication with the remote control. Immergas puts it down to an incompatible remote control, communication problems or dropouts between boiler and remote and, on the Victrix Superior 26-35, also a connection error at the terminals. It says to cut the power and restore it. If the remote is not detected on restart, the Victrix Omnia V2 goes into summer mode and heating cannot be switched on; the Victrix Superior switches to local operation using its own panel.

Warnings and stop conditions

  • Criticaleditorial warning

    If you smell gas: Immergas says to close the meter or main gas tap and, if you can, the boiler's gas tap, open doors and windows, use no naked flames, do not smoke and do not touch switches, sockets, doorbells or phones. Leave the home and call your gas distributor's emergency number from the street.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA)

  • Mediumeditorial warning

    If the boiler does not detect the remote, the Victrix Omnia V2 stays in summer mode and gives no heating. If the home is cold and there are elderly people or babies, call the technician promptly.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA)

Symptoms and causes

Probable causes · in order

  • Incompatible remote controlCommon

    Fits if 31 began when a thermostat or remote was changed or added. Immergas names connection to an incompatible remote and allows only one remote control on the boiler.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA) · Immergas Victrix Superior 26-35, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047096SPA)

  • Communication dropout with the remotePossible

    Fits if the remote used to work and 31 appears now and then. The CARV2 remote is powered through the same two wires that carry data between boiler and remote.

    Evidence: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA) · Immergas Victrix Superior 26-35, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047096SPA)

  • Connection error at the terminalsPossible

    On the Victrix Superior 26-35, Immergas also names a connection error at the terminals. Fits if 31 appears after an installation or electrical work on the boiler.

    Evidence: Immergas Victrix Superior 26-35, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047096SPA)

Virtual technician

Does 31 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Immergas Victrix Omnia V2, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047702SPA) · Immergas Victrix Superior 26-35, instrucciones y advertencias para instalador, usuario y encargado de mantenimiento (1.047096SPA)reviewed 2026-10-04 · verified