CC

Junkers CC on a gas boiler: outdoor sensor not detected

Verified with sources3 sourcesReviewed Oct 3, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

Low

Usually safe to check without specialist tools.

Urgency

Low

Quick answer

Junkers CC means the boiler does not detect the outdoor temperature sensor. From the ground, check whether the sensor on the outside wall or its cable is damaged or pulled off, without opening anything, and ask the technician to test the sensor and cable.

Safety first

Stop and check this first

  • Do not climb onto roofs, high balconies or ladders to check the sensor or its cable. Look from the ground and leave the repair to the technician.
  • If you smell gas: close the gas shut-off valve, open the windows, do not operate switches, put out any flame and, from outside the home, call the gas company and an authorised installer. If you smell flue gases: switch the boiler off, open doors and windows and call the installer.

Safe checks you can perform

  • Whether there is an outdoor sensor
  • Visible sensor cable
  • Sensor and cable test by the technician

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Cable continuity test
  • Do not attempt this professional task: Outdoor sensor reading against its table

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Cable continuity test

    What they doThe technician checks continuity of the sensor cable to its connection at the boiler.

    They must show youthe continuity test.

    In writingwhere the break was and how it was repaired, or the part number of the replaced sensor.

  2. Outdoor sensor reading against its table

    What they doThe technician measures the outdoor sensor's resistance with a multimeter and compares it with the manufacturer's specification for the current temperature.

    They must show youthe measured value against the manufacturer's specification.

    In writingthe value and the conclusion.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Whether there is an outdoor sensor

    No special tools

    Who:
    you.
    How:
    look on the outside walls for a small sensor box with a cable towards the boiler. Look from the ground.
    Result that matters:
    whether there is a sensor and whether it is in place.
    If you find no sensor:
    tell the technician; it may be a setup issue.
    If there is one:
    go on to check the visible cable.
    Evidence to keep:
    a photo of the sensor and where it is.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

  2. Visible sensor cable

    No special tools

    Who:
    you.
    How:
    follow the cable by eye along the wall or trunking, without climbing or pulling it.
    Result that matters:
    whether the cable is cut, crushed or loose.
    If it is damaged:
    Bosch says to check the cable for breaks; show the photo to the technician.
    If it looks intact:
    the break may be in a hidden section or in the sensor itself.
    Evidence to keep:
    photos of the cable route.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

  3. Sensor and cable test by the technician

    Tools required

    Who:
    authorised technician.
    How:
    measures the outdoor sensor and the cable continuity to the boiler.
    Result that matters:
    whether the circuit is open and where.
    If the cable is broken:
    that confirms the cause and it is repaired.
    If the cable is fine and the sensor does not respond:
    it points to the sensor.
    Evidence to keep:
    a report with the measured values.

    Measuring at the boiler terminals means opening it and working near mains voltage: authorised technician only.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Junkers
Product type
Gas boiler

Known code variants

  • C C
  • Cerapur CC
  • Error CC Junkers
  • Junkers C C

What it means

In the CerapurComfort table, CC means the outdoor temperature sensor is not detected; on the ZWE with the TA 211 E controller, that the outdoor sensor has an open circuit. The outdoor sensor feeds weather compensated control, which sets the flow temperature. Bosch says to check that the sensor and its connecting cable have no break. The code points to an open circuit, it does not prove the sensor is broken.

Warnings and stop conditions

  • Mediumeditorial warning

    Do not climb onto roofs, high balconies or ladders to check the sensor or its cable. Look from the ground and leave the repair to the technician.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico

  • Criticalsource verified

    If you smell gas: close the gas shut-off valve, open the windows, do not operate switches, put out any flame and, from outside the home, call the gas company and an authorised installer. If you smell flue gases: switch the boiler off, open doors and windows and call the installer.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

Symptoms and causes

Probable causes · in order

  • Sensor cable cut or disconnectedCommon

    Bosch says to check the cable for breaks. It fits if there has been building work, pruning or damage to the wall the cable runs along.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

  • Faulty outdoor sensorPossible

    If the cable is fine, the sensor may be open circuit. Only measuring it separates the two, not the code.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

  • Sensor set up but not fittedPossible

    If your home has no outdoor sensor and CC appears, the technician should check the controller setup; the code only says it is not detected.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico

Virtual technician

Does CC still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalaciónreviewed 2026-10-03 · verified