E9

Junkers E9 on a gas boiler: temperature limiter tripped

Verified with sources3 sourcesReviewed Oct 3, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

High

Quick answer

Junkers E9 means the heat block temperature limiter or the flue gas temperature limiter has tripped. Read the gauge (Bosch asks for 1 to 1.5 bar), bleed radiators if there is air and reset once.

Safety first

Stop and check this first

  • Never bypass a temperature limiter to get the boiler running: it protects the heat block and the flue. If E9 repeats with correct pressure and no air, a technician must see the boiler.
  • If you smell gas: close the gas shut-off valve, open the windows, do not operate switches, put out any flame and, from outside the home, call the gas company and an authorised installer. If you smell flue gases: switch the boiler off, open doors and windows and call the installer.

Safe checks you can perform

  • System pressure on the gauge
  • Bleeding radiators
  • One reset with the reset key

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Pump and heat block water side test
  • Do not attempt this professional task: Limiter, flow NTC and fuse check

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Pump and heat block water side test

    What they doThe technician checks the pump runs and water passes through the heat block, as Bosch asks for E9.

    They must show youthe pump running and the flow and return temperature difference.

    In writingthe heat block condition and what was cleaned or repaired.

  2. Limiter, flow NTC and fuse check

    What they doThe technician measures the temperature limiters, the flow NTC and the board fuses with a multimeter.

    They must show youthe continuity and NTC readings.

    In writingthe part replaced and why.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. System pressure on the gauge

    No special tools

    Who:
    you.
    How:
    with the system cold, read the gauge. Bosch says below 1 bar you top up with the filling key to 1 to 1.5 bar.
    Result that matters:
    whether pressure is in that range.
    If it was low and you top it up:
    try again; if E9 does not return, pressure was the cause.
    If pressure keeps dropping:
    Bosch says to contact the installer.
    Evidence to keep:
    a photo of the gauge before and after topping up.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  2. Bleeding radiators

    No special tools

    Who:
    you.
    How:
    if a radiator is colder at the top than the bottom, Bosch says to bleed it with the screw at the top; then check the pressure again.
    Result that matters:
    whether air comes out and radiators heat evenly.
    If air came out and E9 does not return after topping up:
    air was the cause.
    If there is no air and E9 returns:
    air is ruled out; call the technician.
    Evidence to keep:
    a note of which radiators had air and the final pressure.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  3. One reset with the reset key

    No special tools

    Who:
    you.
    How:
    if the reset key is flashing, hold it until the display changes; otherwise switch the boiler off and on, as Bosch says.
    Result that matters:
    whether the boiler runs again without E9.
    If it runs:
    keep watch; if E9 repeats, call the service centre.
    If E9 returns straight away:
    do not insist; call the official service centre with the code.
    Evidence to keep:
    a photo of the display with E9 and the date.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Junkers
Product type
Gas boiler

Known code variants

  • 11 E
  • 11E
  • AEG E9
  • AEG hob E9
  • Bosch E9 caldera
  • Cerapur E9
  • E09
  • E-9
  • E9 Worcester
  • error E9 frigorífico Hotpoint
  • error E9 frigorífico Indesit
  • Error E9 Junkers
  • error E9 lavadora Samsung
  • frigorífico combi Hotpoint E9 congelador
  • frigorífico combi Indesit E9 congelador
  • Greenstar E9
  • Hotpoint E9 error fridge freezer
  • Hotpoint E9 frigorífico
  • Hotpoint fridge freezer E9
  • Hotpoint fridge freezer E9 freezer high temperature
  • Indesit E9 error fridge freezer
  • Indesit E9 frigorífico
  • Indesit fridge freezer E9
  • Indesit fridge freezer E9 freezer high temperature
  • Junkers E9
  • lavadora Samsung nivel de agua bajo
  • placa AEG E9
  • placa inducción AEG E9
  • Samsung E9 pierde agua
  • Samsung E9 water leak
  • Samsung lavadora 11E
  • Samsung lavadora E9
  • Samsung washer 11E
  • Samsung washer error E9
  • Samsung washer low water level
  • Samsung washing machine E9
  • Worcester boiler E9 fault
  • Worcester Bosch E9
  • Worcester E9

What it means

On the CerapurComfort, E9 means the heat block temperature limiter or the flue gas temperature limiter has tripped. Bosch says to check the operating pressure, the limiter itself, the pump, the board fuses, bleed the appliance and inspect the water side of the heat block. The ZWE manual adds the flow NTC. It usually means water is not carrying heat away; the code does not say whether pressure, air, the pump or the limiter is to blame.

Warnings and stop conditions

  • Higheditorial warning

    Never bypass a temperature limiter to get the boiler running: it protects the heat block and the flue. If E9 repeats with correct pressure and no air, a technician must see the boiler.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico

  • Criticalsource verified

    If you smell gas: close the gas shut-off valve, open the windows, do not operate switches, put out any flame and, from outside the home, call the gas company and an authorised installer. If you smell flue gases: switch the boiler off, open doors and windows and call the installer.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

Symptoms and causes

Probable causes · in order

  • Low pressure or air in the circuitCommon

    Bosch asks for the operating pressure to be checked and the unit bled. If the gauge is under 1 bar or radiators gurgle, start here.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  • Pump not circulatingPossible

    Bosch includes the pump in its checks. With correct pressure and no air, a stopped pump leaves the heat block without moving water.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

  • Heat block fouled on the water sidePossible

    Bosch asks for the water side of the heat block to be checked; sludge or scale restrict flow even when the pump works.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico

  • Limiter, flow NTC or fusesLess common

    If circulation is good, the limiter, the flow NTC or the board fuses are last on the list; measuring confirms them.

    Evidence: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalación

Virtual technician

Does E9 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Junkers CerapurComfort ZWBC 25-2 C, instrucciones de instalación y manejo para el técnico · Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers ZWE 24-3 y 28-3 H A con Bosch Heatronic, instrucciones de instalaciónreviewed 2026-10-03 · verified

Was this entry useful?