Junkers EF on a gas boiler: boiling detected in the heating

Verified with sources2 sourcesReviewed Oct 4, 2026
Technician coming? See the 3 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

Junkers EF means the boiler detects boiling in the heating or the water does not change temperature when the burner lights. Check the gauge: if it reads below 1 bar, refill to 1 to 1.5 bar and press reset once.

Safety first

Stop and check this first

  • If you smell gas: Bosch says do not smoke or use lighters, do not operate electrical switches or use the phone or doorbell, close the gas valve at the meter or regulator, open doors and windows, warn the neighbours and leave the building. Call your gas distributor's emergency number from the street.
  • Do not leave the boiler running with an empty system: Bosch says it must never be switched on with the appliance or system empty or partly filled. Refill first or wait for the technician.

Safe checks you can perform

  • Gas or flue gas smell near the boiler
  • Pressure on the boiler gauge
  • Refilling with the filling key
  • Bleeding radiators that are cold at the top
  • Air purge, pump and sensors by the technician

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Air purge of boiler and system
  • Do not attempt this professional task: Pump test
  • Do not attempt this professional task: Information menu reading

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Air purge of boiler and system

    What they doThe technician turns on air purge mode 2.2C and checks that the automatic air vent releases trapped air.

    They must show youthe purge function running.

    In writingthat it was purged and the final cold pressure.

  2. Pump test

    What they doRuns test t3 from the test menu: the pump runs for up to 45 seconds and, if it is fine, it can be heard.

    They must show youtest t3 and the result.

    In writingwhether the pump started and what was done.

  3. Information menu reading

    What they doReads i1 current status and i2 last error to see which three digit number comes with EF (349 or 345) and whether it repeats with other codes.

    They must show youthe display with the last error.

    In writingthe codes and cause numbers read.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Gas or flue gas smell near the boiler

    No special tools

    Who:
    you.
    How:
    walk up without pressing switches or turning lights on and notice whether there is a smell of gas or combustion fumes.
    Result that matters:
    whether there is a smell or not.
    If there is a smell:
    do not touch the boiler and follow the gas warning on this page.
    If there is no smell:
    go on to read the pressure gauge.
    Evidence to keep:
    the time and what you noticed.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  2. Pressure on the boiler gauge

    No special tools

    Who:
    you.
    How:
    look at the needle of the gauge on the front with the heating off, without opening anything.
    Result that matters:
    whether it reads below 1 bar, between 1 and 1.5 bar or above.
    If it reads below 1 bar:
    Bosch says the system needs refilling; go to the next step.
    If it is between 1 and 1.5 bar:
    lack of water becomes less likely; air or the other cause on this page become more likely.
    Evidence to keep:
    a photo of the gauge and of the display showing EF and its three digit number.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  3. Refilling with the filling key

    No special tools

    Who:
    you.
    How:
    remove the lower panel as the manual shows, push the blue lever down and release it when the needle is between 1 and 1.5 bar. Then press reset once.
    Result that matters:
    whether the pressure holds and EF clears.
    If you go above 1.5 bar:
    Bosch says to drain a little from one radiator until it is back to 1 to 1.5 bar.
    If the pressure drops again within days:
    Bosch says to call the installer about a permanent drop.
    Evidence to keep:
    the pressure before and after, and the refill date.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  4. Bleeding radiators that are cold at the top

    No special tools

    Who:
    you, if the installer has shown you how.
    How:
    with the boiler off, open the top screw of a radiator that is cold at the top a little until water comes out, then check the gauge again.
    Result that matters:
    whether air came out and how far the pressure drops afterwards.
    If air came out:
    air was part of the problem; refill again to 1 to 1.5 bar.
    If you have to bleed often or see leaks:
    Bosch says the technician should inspect the system.
    Evidence to keep:
    which radiators you bled and the final pressure.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  5. Air purge, pump and sensors by the technician

    Tools required

    Who:
    authorised technician.
    How:
    reads the cause number, turns on air purge mode 2.2C, runs pump test t3 and checks the flow and return sensors.
    Result that matters:
    whether air remains, whether the pump starts and whether the sensors read correctly.
    If air comes out during the purge:
    the air lock is confirmed.
    If there is water and no air:
    the pump and sensors become the suspects.
    Evidence to keep:
    a report with the cause number, the tests done and the final pressure.

    Bosch reserves removing the casing and any internal work for a competent technician. Sensors, pump and board are inside, next to mains voltage parts.

    Evidence: Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Junkers
Product type
Gas boiler

Known code variants

  • Cerapur EF
  • E F
  • EF 345
  • EF 349
  • Error EF Junkers
  • Junkers EF

What it means

On the Cerapur Excellence Compact, EF covers two cause numbers. With 349 the boiler records boiling in heating mode: with the burner at minimum, the difference between flow and return is more than 18 °C. With 345 the flow or return temperature does not change after the burner starts. For excessive flow to return differences Bosch names an air lock or too little water in the circuit. The code does not point to a specific part: it describes how the water behaves inside the boiler.

Warnings and stop conditions

  • Criticaleditorial warning

    If you smell gas: Bosch says do not smoke or use lighters, do not operate electrical switches or use the phone or doorbell, close the gas valve at the meter or regulator, open doors and windows, warn the neighbours and leave the building. Call your gas distributor's emergency number from the street.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  • Highsource verified

    Do not leave the boiler running with an empty system: Bosch says it must never be switched on with the appliance or system empty or partly filled. Refill first or wait for the technician.

    Evidence: Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

Symptoms and causes

Probable causes · in order

  • Too little water in the systemCommon

    Bosch names reduced water content for excessive temperature differences. You can tell because the gauge reads below 1 bar.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

  • Air in the heating circuitPossible

    An air lock is the other cause Bosch gives. It fits if radiators are cold at the top and hot at the bottom, or the system was refilled recently.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

Virtual technician

Does EF still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.