Fb

Junkers FB boiler code: gas valve failed its leak test

Verified with sources2 sourcesReviewed Oct 4, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

High

Quick answer

On the Junkers Cerapur Excellence Compact, FB with number 365 means gas valve stage EV1 did not pass its leak test. Reset once only; if FB returns, leave the boiler off and call a gas engineer as soon as possible.

Safety first

Stop and check this first

  • FB concerns gas valve tightness: if you also smell gas, do not press reset or switch lights or appliances on or off. Close the valve at the meter or regulator, open windows, leave while warning neighbours and call the emergency line from outside.
  • If FB comes back after a single reset, the boiler must stay off until a gas engineer tests the valve; repeated resets do not fix a leaking valve.

Safe checks you can perform

  • Check for any smell of gas near the boiler
  • Write down FB and cause code 365
  • Press reset one time only
  • Gas valve tightness test

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Check gas valve stage EV1
  • Do not attempt this professional task: Test tightness with the boiler running

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Check gas valve stage EV1

    What they doThe gas engineer checks stage EV1, flagged by cause code 365, and repeats the valve leak test.

    They must show youthe valve test result after their check.

    In writingwhether the valve was repaired or replaced.

  2. Test tightness with the boiler running

    What they doAfter the work, they carry out the in-operation tightness check that the installer manual includes in commissioning.

    They must show youthe method and test point used.

    In writingthat the gas installation was left tight.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Check for any smell of gas near the boiler

    No special tools

    Who:
    you, without opening the casing or touching switches.
    How:
    go near the appliance and the meter and only notice whether there is a gas smell; never use a lighter or flame to look.
    Result that matters:
    knowing whether, besides FB, there is a noticeable leak.
    If confirmed:
    if you smell gas, follow this page's safety warning straight away and leave the home.
    If not confirmed:
    with no smell, go on to the single reset and the engineer call.
    Evidence to keep:
    note whether there was a smell and where you noticed it.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  2. Write down FB and cause code 365

    No special tools

    Who:
    you, from the Excellence Compact display.
    How:
    photograph the warning triangle with FB and the number 365 shown underneath; the user manual asks for the fault code and three-digit number when you contact Bosch.
    Result that matters:
    the engineer knowing from the call that this is the EV1 test.
    If confirmed:
    quote FB 365 when booking so they come prepared for the gas valve.
    If not confirmed:
    if the number shown is not 365, note whatever appears: it may be another table row.
    Evidence to keep:
    photo of FB with its cause number.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

  3. Press reset one time only

    No special tools

    Who:
    you, with the reset key on the panel, as the reset section describes.
    How:
    press reset, wait for Reset on the display and watch whether the boiler starts or FB returns with the blue LED flashing.
    Result that matters:
    telling a one-off test failure apart from a valve that fails again.
    If confirmed:
    if FB returns, do not repeat it: leave the boiler off until the visit.
    If not confirmed:
    if the boiler runs, still tell the engineer an FB occurred.
    Evidence to keep:
    time of the reset and what happened after pressing.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación

  4. Gas valve tightness test

    Tools required

    Who:
    registered gas engineer or Junkers authorised service.
    How:
    inspect stage EV1 named by code 365 and carry out the in-operation tightness check described in the commissioning section of the installer manual.
    Result that matters:
    confirming whether the valve closes tightly or there is a real leak.
    If confirmed:
    repair or replace the valve and test tightness again.
    If not confirmed:
    if the valve passes, review the fault history before returning the boiler to service.
    Evidence to keep:
    job sheet with the tightness test result and the part worked on.

    The gas valve and any work with the casing off are reserved for a competent engineer according to the user manual.

    Evidence: Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Junkers
Product type
Gas boiler

Known code variants

  • caldera Junkers FB
  • Cerapur Excellence Compact FB
  • Cerapur FB
  • error Fb lavadora Haier
  • F b
  • FB
  • Haier lavadora Fb
  • Haier washer error Fb
  • Haier washer leakage Fb
  • Haier washer leaking water code Fb
  • Haier washing machine Fb
  • Junkers FB
  • Junkers FB 365
  • lavadora Haier fuga de agua Fb
  • lavadora Haier pierde agua código Fb

What it means

The Cerapur Excellence Compact lockout table gives FB cause code 365, gas valve EV1 leak test failed, with gas valve leak as the possible cause and the reset key as the release. It is the boiler's own self-test of whether one valve stage closes tightly; the other stage, EV2, has its own message (FA 364). The user manual warns that some codes cannot be cleared with a simple reset and that an engineer visit must then be arranged. The code alone does not prove gas is escaping into the home.

Warnings and stop conditions

  • Criticaleditorial warning

    FB concerns gas valve tightness: if you also smell gas, do not press reset or switch lights or appliances on or off. Close the valve at the meter or regulator, open windows, leave while warning neighbours and call the emergency line from outside.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

  • Higheditorial warning

    If FB comes back after a single reset, the boiler must stay off until a gas engineer tests the valve; repeated resets do not fix a leaking valve.

    Evidence: Junkers Cerapur Excellence Compact, instrucciones de uso de la caldera mural a gas de condensación · Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)

Symptoms and causes

Probable causes · in order

  • Internal leak in gas valve stage EV1Common

    For FB 365 the table gives a gas valve leak found during the EV1 test as the possible cause. The boiler locks out so it does not keep running with a valve that does not close tightly.

    Evidence: Junkers Cerapur Excellence Compact ZWB...A..., instrucciones de instalación y manejo para el técnico (6 720 820 575)