Independent technical referenceOfficial site
  • Boilers
  • Gas boiler

EA

Worcester EA fault: flame not detected

Verified with sources3 sourcesReviewed Aug 21, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted combi gas boiler installed in a home
Kai KemmannCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

High

Quick answer

On the documented Greenstar FS CDi and Highflow 440CDi scopes EA means the boiler did not detect a flame. Confirm the exact model because code systems vary across Worcester ranges.

Safety first

Stop and check this first

  • If you smell gas or suspect a leak turn the appliance off do not touch it call 0800 111 999 open doors and windows and follow HSE emergency guidance.
  • EA is documented here only for the named Greenstar scopes. Confirm the exact model manual and do not transfer this meaning to every Worcester boiler.

Safe checks you can perform

  • Record the full Worcester model and the exact EA display
  • Ask the gas supplier to confirm a supply problem
  • Inspect only an accessible external condensate outlet
  • Use only the reset described by the exact manual

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Inspect the gas valve flue and inaccessible condensate route
  • Do not attempt this professional task: Check working gas pressure and the ignition sequence

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Inspect the gas valve flue and inaccessible condensate route

    What they doA competent engineer should test gas-valve operation and inspect internal or inaccessible flue and condensate paths when the model-specific procedure requires it.

  2. Check working gas pressure and the ignition sequence

    What they doA Gas Safe registered engineer should confirm gas presence and working pressure then test the ignition and flame-sensing electrodes and their harnesses against the exact Worcester service instructions.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Record the full Worcester model and the exact EA display

    No special tools

    Photograph the display and identification label without removing the casing. Use the operating instructions for that exact Greenstar model before interpreting or resetting the code.

    Worcester states that its instructions apply only to the models identified in that document.

    Evidence: Worcester Greenstar FS CDi ErP user instructions · Worcester Greenstar Highflow 440CDi ErP installation and servicing instructions

  2. Ask the gas supplier to confirm a supply problem

    No special tools

    If there is no smell of gas and the appliance is not suspected unsafe contact the gas supplier when the household supply appears absent or low. Do not open the boiler or test gas pressure yourself.

    A suspected leak is an emergency and must not be treated as an ordinary EA supply check.

    Evidence: HSE gas safety for homeowners · Worcester Greenstar FS CDi ErP user instructions

  3. Inspect only an accessible external condensate outlet

    No special tools

    From ground level and only if safe look for visible ice or an external obstruction. Worcester permits warm water a hot-water bottle or a warm cloth for a frozen external pipe and says never to use boiling water.

    Do not climb work at height open the boiler or attempt to clear an internal condensate route.

    Evidence: Worcester Greenstar FS CDi ErP user instructions

  4. Use only the reset described by the exact manual

    No special tools

    After a safely accessible frozen condensate pipe has been thawed follow the model instructions for one restart. If EA returns stop and arrange qualified diagnosis.

    A reset does not prove that gas pressure ignition sensing flue or valve conditions are safe.

    Evidence: HSE gas safety for homeowners · Worcester Greenstar FS CDi ErP user instructions

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Boilers
Brand
Worcester Bosch
Product type
Gas boiler

Known code variants

  • Bosch EA caldera
  • caldera Worcester EA
  • Cerapur EA
  • E A
  • E-A
  • EA 227
  • Error EA Junkers
  • error EA Worcester Bosch
  • Junkers EA
  • Worcester boiler EA fault
  • Worcester Bosch EA
  • Worcester EA

What it means

Worcester lists absent or low gas supply and accessible external condensate or flue obstruction in its homeowner checks. Internal gas pressure ignition flame-sensing and gas-valve tests require a Gas Safe registered engineer.

Warnings and stop conditions

  • Criticalsource verified

    If you smell gas or suspect a leak turn the appliance off do not touch it call 0800 111 999 open doors and windows and follow HSE emergency guidance.

    Evidence: HSE gas safety for homeowners

  • Highsource verified

    EA is documented here only for the named Greenstar scopes. Confirm the exact model manual and do not transfer this meaning to every Worcester boiler.

    Evidence: Worcester Greenstar FS CDi ErP user instructions · Worcester Greenstar Highflow 440CDi ErP installation and servicing instructions

Symptoms and causes

Probable causes · in order

  • Flame not detected on the documented Greenstar scopeConfirmed

    Worcester defines EA as flame not detected in the Greenstar FS CDi user instructions and the Greenstar Highflow 440CDi service instructions. The exact product manual still controls the meaning.

    Evidence: Worcester Greenstar FS CDi ErP user instructions · Worcester Greenstar Highflow 440CDi ErP installation and servicing instructions

  • No gas supply or gas pressure below the required levelPossible

    The homeowner guide lists no gas supply or low gas-supply pressure while the service instructions require a competent person to check gas presence and working pressure.

    Evidence: Worcester Greenstar FS CDi ErP user instructions · Worcester Greenstar Highflow 440CDi ErP installation and servicing instructions

  • Accessible external condensate or flue obstructionPossible

    For the Greenstar FS CDi scope Worcester lists a blocked condensate outlet or flue among the EA branches and restricts homeowner observation to conditions that are safe to access.

    Evidence: Worcester Greenstar FS CDi ErP user instructions

  • Ignition flame-sensing or gas-valve faultPossible

    The service instructions list the ignition electrodes and harness flame-sense electrode and harness and gas-valve operation as professional diagnostic branches.

    Evidence: Worcester Greenstar Highflow 440CDi ErP installation and servicing instructions

Virtual technician

Does EA still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

  1. 1

    HSE gas safety for homeowners

    Health and Safety Executive · official_doc

  2. 2

    Worcester Greenstar FS CDi ErP user instructions

    Worcester Bosch · 2015 · manual

Sources: HSE gas safety for homeowners · Worcester Greenstar FS CDi ErP user instructions · Worcester Greenstar Highflow 440CDi ErP installation and servicing instructionsreviewed 2026-08-21 · verified

Was this entry useful?