- EV charging
- EV charger
Contactor Fault
myenergi zappi Contactor Fault (Fault code 28) on an EV charger: welded relay contact

Risk level
High
Professional inspection is recommended.
Urgency
High
Quick answer
The zappi detected a welded contact on its internal relay and opened the secondary relay to isolate the car. Unplug the car and press and hold the reset button; if it returns, stop using it.
Safety first
Stop and check this first
- If Contactor Fault persists, myenergi says to stop using the zappi. A welded relay affects how the output to the vehicle is disconnected.
Safe checks you can perform
- Unplug the car and reset
- Switch off the charger circuit if the alert stays
- Relay and output inspection
Leave these tasks to a qualified professional
- Do not attempt this professional task: Proving the output is dead
- Do not attempt this professional task: Insulation resistance and RCD trip test
- Do not attempt this professional task: Documented replacement
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Proving the output is dead
What they doThe technician checks with a voltage tester that the output to the vehicle has no voltage when the zappi is not charging.
They must show youthe output reading dead at rest.
In writingmeasured values and relay condition.
Insulation resistance and RCD trip test
What they doMeasures insulation resistance on the charger circuit and trip tests the RCD or RCBO protecting it.
They must show youinsulation readings and trip time.
In writingvalues against the specification and the conclusion.
Documented replacement
What they doIf the welded contact is confirmed, the service technician repairs or replaces the unit and runs several full charges.
They must show youseveral sessions without Contactor Fault.
In writingpart or unit replaced, reference, serial number and reason.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Unplug the car and reset
- Who:
- you, no tools.
- How:
- unplug the car and press and hold the zappi reset button, as the manual says.
- Result that matters:
- whether Contactor Fault returns.
- If it does not return:
- note it; a relay that welded once needs watching.
- If it returns:
- confirms the detection; stop using the zappi and contact myenergi or your installer.
- Evidence to keep:
- photo of the screen, date and number of resets done.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Switch off the charger circuit if the alert stays
- Who:
- you, only operating the consumer unit switch.
- How:
- if the alert persists, switch off the circuit breaker feeding the zappi so it stays dead until inspected.
- Result that matters:
- the charger is off and not used.
- If the charger goes off with that breaker:
- the circuit is correctly identified.
- If you do not know which breaker it is:
- do not try at random; wait for the installer.
- Evidence to keep:
- photo of the breaker off and its circuit label.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Relay and output inspection
- Who:
- myenergi service technician or qualified electrician.
- How:
- with the unit isolated, inspect the relay and verify with instruments that the output is dead when it should be off.
- Result that matters:
- whether the contact is welded and whether the output stays isolated.
- If the contact is welded:
- confirms the fault and requires repair or replacement.
- If the relay opens correctly in the test:
- moves the focus to the history and the vehicle load.
- Evidence to keep:
- report with the relay check.
Testing a relay and measuring output voltage is mains voltage work. Technician only.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- EV charging
- Brand
- myenergi
- Product type
- EV charger
Known code variants
- zappi Contactor Fault
- zappi error 28 relé soldado
- zappi fault code 28
- zappi welded relay
What it means
myenergi defines Fault code 28 as the zappi internal relay having a welded contact. To keep the output to the vehicle isolated, the unit opens the secondary relay. In other words, protection has already acted, but the main relay does not open as it should. The code reports the relay state, not what caused it, and only a technical inspection confirms whether the relay is damaged.
Warnings and stop conditions
- Highsource verified
If Contactor Fault persists, myenergi says to stop using the zappi. A welded relay affects how the output to the vehicle is disconnected.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Symptoms and causes
Probable causes · in order
- Main relay contact weldedCommon
This is the condition the zappi reports. If the alert returns after a reset, detection persists and a technician must inspect the relay.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
- One-off detection that does not repeatPossible
If after unplugging and resetting the zappi charges and the alert does not return, still record it for the technician.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Virtual technician
Does Contactor Fault still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
myenergi · 2023 · manual