- EV charging
- EV charger
109
Wallbox error 109 on EV charger: grid voltage out of UK limits

Risk level
Medium
Proceed carefully and stop if the check is unclear.
Urgency
Medium
Quick answer
Wallbox code 109 means the voltage between L1 and neutral is outside the limits set by UK regulations, so the charger stops. It usually clears itself once the grid settles; if not, restart the charger and call a certified electrician.
Safety first
Stop and check this first
- Measuring L1 to N means working on live terminals: Wallbox reserves it for a certified electrician, so do not attempt it yourself.
Safe checks you can perform
- Give the grid a few minutes to settle
- Power the charger off, unplug the car and retry
- Look for other signs of voltage trouble at home
Leave these tasks to a qualified professional
- Do not attempt this professional task: L1 to N voltage measurement
- Do not attempt this professional task: Report to the electricity network operator
- Do not attempt this professional task: Wallbox warranty case if the voltage is correct
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
L1 to N voltage measurement
What they doThe certified electrician measures the Wallbox supply voltage between L1 and neutral and compares it with the 210 to 254 V range the manufacturer gives.
They must show youthe L1 to N voltage measured at the charger terminals and at the board, idle and while charging.
In writingthe measured values, when they were taken and whether they fell outside 210 to 254 V.
Report to the electricity network operator
What they doIf the measured voltage is out of range, the installer or account holder reports the supply problem to the company that runs the network.
They must show youthe measurement record that backs up the report to the supplier.
In writingthe date of the report, the incident reference and the readings handed over.
Wallbox warranty case if the voltage is correct
What they doWith voltage in range and 109 still active, the installer opens a case with Wallbox, attaching the checklist and photos.
They must show youthe correct voltage reading and the firmware version shown in the app.
In writingthe case number, the firmware version and any part replaced.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Give the grid a few minutes to settle
- Who:
- you, from the Wallbox app, without touching the consumer unit.
- How:
- leave the car as it is and watch whether code 109 disappears by itself; Wallbox explains that the charger clears it once the grid voltage becomes stable again.
- Result that matters:
- learning whether it was a brief supply swing or a problem that persists.
- If the error clears and charging resumes:
- note the time in case it happens again at other times of day.
- If 109 is still showing after several minutes:
- move on to the restart Wallbox suggests.
- Evidence to keep:
- a screenshot of the app with code 109, date and time.
Evidence: Understanding Wallbox app Error Codes and How to Resolve Them · Troubleshooting Guide B for Installer Onsite and Charger Offline
Power the charger off, unplug the car and retry
- Who:
- you, following the step Wallbox assigns to the user.
- How:
- switch the charger off, unplug the cable from the car, switch the charger back on and start a fresh session; do not open the casing or handle wiring to do this.
- Result that matters:
- checking whether the voltage lockout goes away after a clean start of the unit.
- If it charges normally:
- watch whether 109 returns at certain hours, which points to the grid rather than the car.
- If the code comes straight back:
- stop retrying and ask a certified electrician to measure the voltage.
- Evidence to keep:
- a note of when you restarted and what the app showed afterwards.
Evidence: Understanding Wallbox app Error Codes and How to Resolve Them
Look for other signs of voltage trouble at home
- Who:
- you, indoors, without opening anything.
- How:
- notice whether flickering lights, appliances that reboot or local outages happen at the same time the Wallbox shows 109.
- Result that matters:
- giving the electrician and the supplier clues that the issue sits in the supply.
- If other symptoms appear in the house or the street:
- tell the electrician and keep the times.
- If only the charger raises the alert:
- L1 and N still need measuring at the charger supply.
- Evidence to keep:
- a list of times with symptoms and the appliances affected.
Evidence: Understanding Wallbox app Error Codes and How to Resolve Them
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- EV charging
- Brand
- Wallbox
- Product type
- EV charger
Known code variants
- código de error 109 app Wallbox
- Error 109 Wallbox
- Wallbox 109 Protective Earth
- Wallbox 109 Protective Earth Reino Unido
- Wallbox 109 tensión L1 N fuera de límites
- Wallbox 109 voltage L1 N outside limits
- Wallbox app error 109
- Wallbox código 109
- Wallbox error code 109
- Wallbox Pulsar error 109
- Wallbox Pulsar Plus error 109 UK
What it means
On the Wallbox app error codes page (updated 24/01/2025), 109 means the charger measures a voltage between L1 and N outside the limits defined by UK regulations and stops operating. The Wallbox installer guide labels it 'Protective Earth' and lists it for UK chargers only; when the voltage returns to a correct value for a stable window of about 2 minutes, the error clears by itself. The code alone never proves that a charger part has failed, and other models or firmware versions may behave differently.
Warnings and stop conditions
- Mediumsource verified
Measuring L1 to N means working on live terminals: Wallbox reserves it for a certified electrician, so do not attempt it yourself.
Evidence: Understanding Wallbox app Error Codes and How to Resolve Them
Symptoms and causes
Probable causes · in order
- Unstable or out-of-range grid voltageCommon
Wallbox says the charger sees an L1 to N voltage outside the accepted range; the electrician should contact the supplier if the reading is below 210 V or above 254 V.
Evidence: Understanding Wallbox app Error Codes and How to Resolve Them · Troubleshooting Guide B for Installer Onsite and Charger Offline
- Short-lived supply fluctuationPossible
According to Wallbox, once the grid voltage stabilises the charger clears 109 on its own, so a brief spike or dip may be the whole story behind the alert.
Evidence: Understanding Wallbox app Error Codes and How to Resolve Them · Troubleshooting Guide B for Installer Onsite and Charger Offline
- Internal fault with correct voltageLess common
The installer guide allows that if the measured voltage sits between 210 and 254 V and the error persists, a replacement might be needed after opening a case with Wallbox.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
Virtual technician
Does 109 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
Understanding Wallbox app Error Codes and How to Resolve Them
Wallbox · 2025 · official_doc
- 2
Comprender los códigos de error de la aplicación Wallbox y cómo resolverlos
Wallbox · 2025 · official_doc
- 3
Troubleshooting Guide B for Installer Onsite and Charger Offline
Wallbox · 2025 · official_doc