- EV charging
- EV charger
111
Wallbox error 111 on EV charger: ground monitor fault

Risk level
High
Professional inspection is recommended.
Urgency
High
Quick answer
Wallbox 111 ('Ground Monitor') means the charger believes the protective earth is disconnected or sees too high a resistance or voltage. Do not use the charger or touch wiring: call a certified electrician to check the earth.
Safety first
Stop and check this first
- A charger that thinks it has lost its earth should not be used: keep away from damaged cables and the casing, and leave the earth conductor to a certified electrician.
Safe checks you can perform
- Stop charging and note the exact code
- Think back to recent electrical work
- Gather the details Wallbox asks for in a case
Leave these tasks to a qualified professional
- Do not attempt this professional task: Charger earth connection inspection
- Do not attempt this professional task: Earth to neutral voltage measurement
- Do not attempt this professional task: Wallbox case for the ground monitor
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Charger earth connection inspection
What they doThe certified electrician checks that the protective earth is connected at the Wallbox input and output and measures the earth loop impedance.
They must show youthe earth conductor continuity and the earth loop impedance or earth electrode resistance reading.
In writingthe readings taken and which connection was tightened or remade.
Earth to neutral voltage measurement
What they doWith a multimeter, the electrician measures the voltage between protective earth and neutral to tell whether the cause is the supply or the unit.
They must show youthe earth to neutral voltage measured at the charger terminals.
In writingthe value measured and whether it exceeded the 10 V Wallbox cites.
Wallbox case for the ground monitor
What they doIf the earth is properly connected and the voltage is low, the installer opens a case with Wallbox for a possible ground monitor failure.
They must show youthe correct earth readings and the charger firmware version.
In writingthe case number, the readings supplied and any part replaced.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Stop charging and note the exact code
- Who:
- you, from the Wallbox app or the platform you use.
- How:
- stop any charging attempt, unplug the car if the cable releases normally, and take a screenshot of code 111 exactly as shown.
- Result that matters:
- not carrying on with a charger that may have no earth, and keeping the detail for the electrician.
- If the code stays on:
- do not keep restarting; wait for the earth inspection.
- If the cable will not release or you notice heat or a burning smell:
- switch off the charger breaker if safe and call the electrician.
- Evidence to keep:
- a screenshot showing 111, date, time and charger model.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
Think back to recent electrical work
- Who:
- you, going over the last few weeks.
- How:
- consider whether anyone worked on the consumer unit, a junction box, the charger circuit or the property earth shortly before the code appeared.
- Result that matters:
- pointing the electrician towards an earth connection that may have been left loose or poorly tightened.
- If there was recent electrical work:
- tell the electrician and, if you can, who carried it out.
- If nobody touched anything:
- say so too, as it rules out a recent fitting error.
- Evidence to keep:
- dates of any work and the name of the installer involved.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
Gather the details Wallbox asks for in a case
- Who:
- you, before speaking to the installer or support.
- How:
- find the charger serial number in the app or on the label and note the car make and model, together with screenshots and outside photos of the unit.
- Result that matters:
- letting the electrician open a case with Wallbox straight away if the earth turns out to be fine.
- If you have everything:
- hand it to the electrician with the 111 screenshot.
- If you cannot find the serial number:
- do not open the casing to look, the installer will locate it.
- Evidence to keep:
- serial number, outside photos and app screenshots.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- EV charging
- Brand
- Wallbox
- Product type
- EV charger
Known code variants
- Error 111 Wallbox
- Wallbox 111 Ground Monitor
- Wallbox 111 protective earth disconnected
- Wallbox 111 tierra desconectada
- Wallbox charger earth fault 111
- Wallbox código 111
- Wallbox error 111 tierra de protección
- Wallbox error code 111
- Wallbox Pulsar error 111
What it means
In the Wallbox installer guide (Troubleshooting Guide B, updated 01/04/2025), code 111 'Ground Monitor' appears when the charger detects too high a resistance or voltage and concludes that the protective earth conductor has been disconnected. Wallbox asks for the earth to be checked at the charger input and output and for the voltage between earth and neutral to be measured. The code is not listed on the user-facing app codes page. The code alone never proves that a part has failed, and other models or firmware may act differently.
Warnings and stop conditions
- Highsource verified
A charger that thinks it has lost its earth should not be used: keep away from damaged cables and the casing, and leave the earth conductor to a certified electrician.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
Symptoms and causes
Probable causes · in order
- Protective earth disconnectedCommon
Wallbox explains that the charger reads the earth conductor as loose or missing, so the installer must verify its connection at both the input and the output.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
- High voltage between earth and neutralPossible
If the electrician measures more than 10 V between protective earth and neutral, the Wallbox guide says to contact the electrical provider because the cause lies in the supply.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
- Charger ground monitor brokenLess common
When the earth to neutral voltage is low and the alert persists, Wallbox treats the unit's earth monitoring circuit as broken, and a replacement might be needed.
Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline
Virtual technician
Does 111 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
Troubleshooting Guide B for Installer Onsite and Charger Offline
Wallbox · 2025 · official_doc
Was this entry useful?