Independent technical referenceOfficial site
  • EV charging
  • EV charger

114

Wallbox error 114 on EV charger: low-level CP signal fault

Verified with sources3 sourcesReviewed Oct 18, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted EV charger (wallbox) with charging cable
Solomon203CC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

Wallbox code 114 ('Control Pilot High Undefined') appears when the control pilot voltage during the low-level period has an unexpected value. Unplug the EV gun from the car and check whether the halo turns green; if it stays on, call your installer.

Safety first

Stop and check this first

  • Viewing internal LED302 blinks, measuring CP-PE or checking the flat Molex cable requires opening the charger casing: leave those steps strictly to a certified electrician.

Safe checks you can perform

  • Unplug the EV gun from the car and watch the Halo colour
  • Remove any adapters or extenders and inspect the outer cable
  • Update the charger software and run an app restore

Leave these tasks to a qualified professional

  • Do not attempt this professional task: CP-PE voltage measurement and internal Molex ribbon check
  • Do not attempt this professional task: Factory restore verification and Wallbox Partner Portal claim

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. CP-PE voltage measurement and internal Molex ribbon check

    What they doA certified electrician measures the DC voltage between control pilot (CP) and protective earth (PE), checks continuity along the CP wire, and inspects and cleans the internal flat Molex cable pins.

    They must show youthe DC voltage reading between CP and PE and the 14 blinks on internal indicator LED302.

    In writingthe measured CP-PE values, the condition of the Molex connector and whether the Halo turned green with the gun unplugged.

  2. Factory restore verification and Wallbox Partner Portal claim

    What they doIf error 114 remains present in factory settings, the installer completes the official Wallbox checklist with photos and submits a case through the webform or Partner Portal.

    They must show youthe checklist photos required by Wallbox and confirmation that the error persists in factory settings.

    In writingthe Wallbox case reference, the firmware version and any unit or cable replacement carried out.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Unplug the EV gun from the car and watch the Halo colour

    No special tools

    Who:
    you, next to the vehicle, without tools.
    How:
    disconnect the EV gun from the car inlet, rest it in its holster without pulling on the lead, and check whether the Wallbox Halo or front LED changes from red to green as required by the guide's initial step.
    Result that matters:
    finding out whether the charger clears the fault as soon as it is isolated from the vehicle.
    If the Halo turns green once unplugged:
    make sure the charger software is updated in the Wallbox app and try charging again without adapters.
    If the LED stays red with the car unplugged:
    note down error 114 and continue with the non-intrusive checks below.
    Evidence to keep:
    a photo of the Halo LED with the EV gun unplugged and a screenshot of code 114 in the app.

    Evidence: Understanding Wallbox app Error Codes and How to Resolve Them · Troubleshooting Guide B for Installer Onsite and Charger Offline

  2. Remove any adapters or extenders and inspect the outer cable

    No special tools

    Who:
    you, visually checking the external cable while charging is stopped.
    How:
    confirm that no Type 1/Type 2 adapter or extension cable is fitted between the EV gun and the vehicle, uncoil the lead so it runs straight, and look for signs of strain or damage on the plug without touching the pins.
    Result that matters:
    ruling out accessories that Wallbox advises against or visible cable strain affecting the pilot signal.
    If an adapter or coiled cable was present and removing it restores normal charging:
    stop using that accessory.
    If you spot physical damage on the gun or code 114 returns on a direct connection:
    stop using the charger and contact your installer.
    Evidence to keep:
    photos of the EV gun connector, the uncoiled lead and the vehicle inlet.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

  3. Update the charger software and run an app restore

    No special tools

    Who:
    you, from your phone in the Wallbox app with the car unplugged.
    How:
    check in the Wallbox app that the charger firmware is up to date first and, if code 114 persists on retry, run a charger restore through the Wallbox app without opening the enclosure.
    Result that matters:
    testing whether returning the charger to factory settings via the app clears the pilot error.
    If the fault stays away after the update or app restore:
    note the firmware version now running.
    If error 114 remains even in factory settings:
    gather the serial number so your installer can open a case with Wallbox.
    Evidence to keep:
    a screenshot of the firmware version, the charger serial number and the car make and model.

    Evidence: Understanding Wallbox app Error Codes and How to Resolve Them · Troubleshooting Guide B for Installer Onsite and Charger Offline

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
EV charging
Brand
Wallbox
Product type
EV charger

Known code variants

  • Error 114 Wallbox
  • LED302 14 parpadeos Wallbox
  • Wallbox 114 Control Pilot High Undefined
  • Wallbox 114 control pilot low level
  • Wallbox 114 piloto de control
  • Wallbox código 114
  • Wallbox error code 114
  • Wallbox LED302 14 blinks
  • Wallbox Pulsar error 114
  • Wallbox Pulsar Plus error 114

What it means

In Wallbox's Troubleshooting Guide B for installers (updated 01/04/2025), error #114 'Control Pilot High Undefined' means the voltage on the control pilot (CP) line during the low-level period has an unexpected value, while internal indicator LED302 blinks 14 times. Wallbox marks this code as recoverable and instructs removing the EV gun first to see whether the Halo or status LED turns green before considering a unit replacement in factory settings. Code 114 by itself never proves that a hardware component has failed, and behaviour can vary by charger model or firmware.

Warnings and stop conditions

  • Mediumsource verified

    Viewing internal LED302 blinks, measuring CP-PE or checking the flat Molex cable requires opening the charger casing: leave those steps strictly to a certified electrician.

    Evidence: Understanding Wallbox app Error Codes and How to Resolve Them · Troubleshooting Guide B for Installer Onsite and Charger Offline

Symptoms and causes

Probable causes · in order

  • Unexpected CP low-level voltage while connected to the carCommon

    Wallbox's guide explains that the charger detects an out-of-range value during the low-level period of the control pilot signal, so unplugging the EV gun is the primary test.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

  • Adapters, extension leads or strained EV gun cablePossible

    In the same troubleshooting guide, Wallbox warns that Type 1 to Type 2 adapters, extension leads or a pulled EV gun cable disrupt control pilot communication.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

  • Loose internal Molex flat cable or persistent fault in factory settingsLess common

    Wallbox notes that a poorly seated flat Molex ribbon causes CP voltage fluctuations and that if #114 remains after a factory restore, a replacement may be needed.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

Virtual technician

Does 114 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Understanding Wallbox app Error Codes and How to Resolve Them · Comprender los códigos de error de la aplicación Wallbox y cómo resolverlos · Troubleshooting Guide B for Installer Onsite and Charger Offlinereviewed 2026-10-18 · verified

Was this entry useful?