Wallbox error 116 on EV charger: multiple network primaries

Verified with sources3 sourcesReviewed Oct 18, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted EV charger (wallbox) with charging cable
Solomon203CC BY-SA 4.0Image source

Risk level

Low

Usually safe to check without specialist tools.

Urgency

Medium

Quick answer

Wallbox code 116 ('Static Load Management, multiple primaries') means more than one charger has been set as primary on the network. In the app or portal, remove Static Load Management from all chargers except one and restore the others.

Safety first

Stop and check this first

  • Adjusting the internal current selector or CANBUS/PRWBST switch and measuring resistance across CAN L and CAN H requires opening the isolated charger: leave it to a certified installer.

Safe checks you can perform

  • Check the app or portal and leave only one primary charger
  • Restore the chargers that were configured as masters via the app
  • Watch the front LED for Secondaries error or Stand-alone mode

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Static Load Management reconfiguration and internal switch check
  • Do not attempt this professional task: 60-ohm resistance test across the inter-charger bus

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Static Load Management reconfiguration and internal switch check

    What they doThe installer connects to the primary charger via Bluetooth and verifies the EMS setup, the rotary current selector position, and the CANBUS or PRWBST switch on every charger.

    They must show youthe app showing a single primary paired with its secondaries and the switch positions inside each unit.

    In writingthe primary serial number, the paired secondary serial numbers and the selector and switch settings.

  2. 60-ohm resistance test across the inter-charger bus

    What they doWith power switched off, the electrician measures resistance with all bus cables connected (between CAN L and CAN H on Pulsar Plus, Copper SB and Commander 2/2s, or between D+ and D- on Pulsar Pro/Max) to confirm it reads 60 ohms.

    They must show youthe multimeter reading of 60 ohms across CAN L/CAN H or D+/D- with all bus cables attached.

    In writingthe measured resistance in ohms, any termination switch change and the Wallbox case number if escalated.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Check the app or portal and leave only one primary charger

    No special tools

    Who:
    you or the site administrator, from the Wallbox app or portal.
    How:
    connect via Bluetooth or sign in to the Wallbox portal, open the Static Load Management settings on each charger in the group, and remove the Static Load Management configuration from every unit except the single primary.
    Result that matters:
    keeping just one primary charger on the network, which is Wallbox's first step for clearing code 116.
    If code 116 clears automatically once only one primary remains:
    verify that the group shares load as expected.
    If the alert stays active after removing the extra primaries:
    move on to restoring the affected chargers.
    Evidence to keep:
    screenshots of the Static Load Management settings on each unit before and after the change.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

  2. Restore the chargers that were configured as masters via the app

    No special tools

    Who:
    you, using the Wallbox app without opening any charger cover.
    How:
    follow step two in Wallbox's #116 table: restore the chargers that had been configured as masters through the app, then pair them again as secondary chargers under the single primary unit.
    Result that matters:
    clearing the conflicting master roles so the auto-recoverable error resets cleanly.
    If all units pair without errors:
    record which serial number is the designated primary charger.
    If they still fail to pair from the app:
    check the front LED colour pattern and call your installer.
    Evidence to keep:
    a list of charger serial numbers showing the single primary and each secondary unit.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

  3. Watch the front LED for Secondaries error or Stand-alone mode

    No special tools

    Who:
    you, looking at the front of the chargers without touching wiring.
    How:
    note whether the front LED turns red for 30 seconds ('Secondaries error' when secondary chargers are misconfigured) or blinks green, white and turquoise alternatively ('Stand-alone mode' when the misconfiguration is on the primary).
    Result that matters:
    telling from outside whether the remaining Static Load Management mismatch sits on the secondaries or on the primary.
    If you identify which LED pattern appears on each unit:
    pass that detail to your installer.
    If the front light stays solid red and code 116 remains:
    ask the installer to inspect the communication bus.
    Evidence to keep:
    a short video of the front LED sequence on each charger in the group.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline · Pulsar Plus & Pulsar Plus Socket Status LED Lights - Colours' meaning

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
EV charging
Brand
Wallbox
Product type
EV charger

Known code variants

  • Error 116 Wallbox
  • LED302 16 parpadeos Wallbox
  • Wallbox 116 Static Load Management multiple primaries
  • Wallbox código 116
  • Wallbox error code 116
  • Wallbox error secundarios LED rojo 30 segundos
  • Wallbox LED302 16 blinks
  • Wallbox multiple primary chargers
  • Wallbox Secondaries error red LED 30s
  • Wallbox varios cargadores primarios

What it means

In Wallbox's Troubleshooting Guide B for installers (updated 01/04/2025), error #116 'Static Load Management, multiple primaries' occurs when the user or installer has configured more than one charger as primary on the same load-sharing network, while internal LED302 blinks 16 times. On the Pulsar Plus LED meanings page, Static Load Management pairing issues also show on the front light as red for 30 seconds or alternating green, white and turquoise. The code is auto-recoverable and on its own never proves that a charger is defective.

Warnings and stop conditions

  • Mediumsource verified

    Adjusting the internal current selector or CANBUS/PRWBST switch and measuring resistance across CAN L and CAN H requires opening the isolated charger: leave it to a certified installer.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

Symptoms and causes

Probable causes · in order

  • More than one charger configured as primary in the app or portalCommon

    Wallbox states that code 116 is triggered when more than one charger on the network holds the Static Load Management primary role at the same time.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

  • Pairing mismatch between the primary and secondary chargersPossible

    On its Pulsar Plus status LED page, Wallbox notes that Static Load Management misconfiguration either prevents secondaries from pairing or puts the primary into stand-alone mode.

    Evidence: Pulsar Plus & Pulsar Plus Socket Status LED Lights - Colours' meaning

  • Incorrect CANBUS/PRWBST switch position or 60-ohm bus terminationLess common

    For Static Load Management installation issues, Wallbox's guide instructs checking the termination switch and measuring 60 ohms across CAN L and CAN H or across D+ and D-.

    Evidence: Troubleshooting Guide B for Installer Onsite and Charger Offline

Virtual technician

Does 116 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Troubleshooting Guide B for Installer Onsite and Charger Offline · Pulsar Plus & Pulsar Plus Socket Status LED Lights - Colours' meaning · Pulsar Plus & Pulsar Plus Socket Status LED Lights - Significado de los coloresreviewed 2026-10-18 · verified

Was this entry useful?