Independent technical referenceOfficial site
  • HVAC
  • Smoke and CO alarms

ALARMA-CO-4-CHIRRIDOS

FireAngel FA6813 four-chirp red alarm on CO detector: danger

Verified with sources1 sourceReviewed Oct 4, 2026
Technician coming? See the 3 steps they must show you
Google Nest Protect smoke and carbon monoxide alarm with its light ring glowing blue
Raysonho @ Open Grid Scheduler / Grid EngineCC0Image source

Risk level

Critical

Stop using the equipment and contact a professional.

Urgency

Immediate

Quick answer

Get everyone out into fresh air now, call 112 or your local emergency number if anyone has a headache or nausea, and stay out until emergency services say it is safe. Four repeated chirps with a red flash on the FA6813 warn of dangerous carbon monoxide.

Safety first

What to do now

  • Get everyone into fresh air and call 112 if anyone feels ill

    Who: you and everyone in the home, without staying behind to look for the source. How: open doors and windows only if they are on your way out and it is safe; FireAngel asks you to stop using fuel-burning appliances and turn them off if possible, so do that only if you pass them anyway and without lingering. Result that matters: nobody keeps breathing air that contains carbon monoxide while help is on the way. If someone has a headache, nausea, dizziness or drowsiness: call 112 or your local emergency number and say you suspect carbon monoxide poisoning. If nobody has symptoms: stay outside and ring your gas or fuel supplier's emergency number, as the manual instructs. Evidence to keep: the time the alarm started and who was inside.

  • Stay outside until you are told it is safe to return

    Who: every occupant, waiting outdoors or at a neighbour's. How: FireAngel warns that, depending on the CO level, it can take up to 10 minutes for the sensor to clear and the alarm to stop; do not go in while it sounds and, even once it stops, wait for emergency services to say so. Result that matters: avoiding a return to a home where the gas has not yet cleared. If it is still sounding after that time: keep everyone out and call 112 again if nobody has arrived yet. If it has stopped: do not light the boiler, stove or cooker until a gas engineer has checked them. Evidence to keep: the time the alarm stopped and who cleared you to go back in.

  • Use the Test button silence only the way FireAngel describes

    Who: you, and only after ventilating and evacuating if the cause of the alarm is unknown. How: the manual explains that pressing the Test button silences the sounder for 5 minutes, but it will not silence if more than 150 ppm has been detected and it sounds again if CO rises above 180 ppm. Result that matters: not mistaking a silenced alarm for a sign that the danger is over. If the alarm refuses to silence: CO is high, so leave and wait for help outdoors. If it goes quiet and starts again a little later: carbon monoxide is still present, leave the home again. Evidence to keep: whether you silenced it, at what time and whether it came back on.

  • When you come home, look for a double red flash

    Who: you, if you were out when the alarm went off. How: FireAngel says that if nobody silences it, the alarm sounds until CO drops below 50 ppm and then the red light flashes twice every 40 seconds for 7 days to let you know. Result that matters: learning that dangerous CO was present while you were away even though nothing can be heard now. If you see that double red flash: ventilate, keep fuel-burning appliances off and call a gas engineer. If a family member feels unwell on entering: go back out and call 112. Evidence to keep: a short video of the light pattern and the date you found it.

What you must never do

  • Do not attempt this professional task: Emergency services for suspected poisoning
  • Do not attempt this professional task: FireAngel Technical Support enquiry
  • Do not attempt this professional task: Check of every fuel-burning appliance

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Emergency services for suspected poisoning

    What they doEmergency services treat anyone with symptoms and, where needed, send the fire service to measure CO and ventilate the property.

    They must show youthe CO reading they took indoors and in which rooms.

    In writingthe incident number, the time of attendance and whether you were allowed back in.

  2. FireAngel Technical Support enquiry

    What they doIf after the incident the alarm neither sounds nor flashes red when you hold Test, FireAngel Technical Support assesses a replacement.

    They must show youthe alarm batch number and the date printed next to REPLACE BY.

    In writingthe support case number and what FireAngel decided about the warranty.

  3. Check of every fuel-burning appliance

    What they doA qualified gas engineer inspects the boiler, heaters, cooker, stoves, chimneys and flues before you use them again.

    They must show youthe flue gas analysis of each appliance and the draught of chimneys and flues.

    In writingwhich appliance produced the CO, the repair carried out and whether each one is safe to use.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
HVAC
Brand
FireAngel
Product type
Smoke and CO alarms

Known code variants

  • detector de monóxido FireAngel pitando
  • FireAngel alarma de CO luz roja
  • FireAngel carbon monoxide alarm going off
  • FireAngel CO alarm 4 chirps red light
  • FireAngel CO detector won't stop beeping
  • FireAngel detector CO suena sin parar
  • FireAngel FA6813 alarm sounding
  • FireAngel FA6813 alarma monóxido de carbono
  • FireAngel FA6813 red flash beeping
  • FireAngel FA6813 suena 4 chirridos

What it means

Get everyone outside, call 112 or your local emergency number if anyone has symptoms, and do not go back in until emergency services allow it. In the FireAngel FA6813 user manual (section 3), a loud signal of four repeated chirps at 85 dB with a red flash at the same time means the alarm has measured dangerous CO levels; it reacts faster the higher the concentration and sounds within 3 minutes at 300 ppm or more. The sound alone never proves that a part has failed: always treat it as a real emergency. Other FireAngel models may signal differently.

Warnings and stop conditions

  • Criticalsource verified

    Never remove the batteries or cover the FA6813 to stop the noise: the manual only allows silencing with the Test button, and above 150 ppm even that does not work.

    Evidence: FA6813 Carbon Monoxide Alarm User Manual

  • Highsource verified

    A quiet sounder does not prove the air is safe: keep fuel-burning appliances off until a gas engineer has inspected them.

    Evidence: FA6813 Carbon Monoxide Alarm User Manual

Sources and technical references

  1. 1

    FA6813 Carbon Monoxide Alarm User Manual

    FireAngel · 2023 · manual

Sources: FA6813 Carbon Monoxide Alarm User Manualreviewed 2026-10-04 · verified

Was this entry useful?