- Appliances
- Dryers
C6
AEG dryer C6: humidity-sensing fault

Risk level
High
Professional inspection is recommended.
Urgency
High
Quick answer
C6 means the dryer has a humidity-measurement problem; AEG also links it to cycles exceeding about 4.5 hours. Preserve the full display and model, then use actual elapsed time, load moisture at stop and whether the appliance has a correctly earthed socket history to choose the next branch before any part or paid repair.
Safety first
Stop and check this first
- Stop immediately for water near electricity, smoke, burning smell, abnormal heat, damaged cable or repeated breaker trips. Close the water tap when a leak is possible; sealed water, heat and mains circuits are professional-only.
Safe checks you can perform
- Capture the decision evidence
- Run the one discriminating check
- Stop at the result boundary
Leave these tasks to a qualified professional
- Do not attempt this professional task: Evidence-led AEG handoff for C6
What a technician must be able to justify
A technician is coming
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Evidence-led AEG handoff for C6
What they doA qualified technician should test household earth, accessible sensing bars, moisture sensor circuit, harness or control, using the exact model/PNC and the recorded result for actual elapsed time, load moisture at stop and whether the appliance has a correctly earthed socket history.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Checks and evidence, step by step
Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
- 1
Capture the decision evidence
No special tools
Procedure
Photograph C6, the complete message and model/PNC. Record the failed programme stage and actual elapsed time, load moisture at stop and whether the appliance has a correctly earthed socket history. Do not clear the history repeatedly.
Stop immediately for water near electricity, smoke, burning smell, abnormal heat, damaged cable or repeated breaker trips. Close the water tap when a leak is possible; sealed water, heat and mains circuits are professional-only.
Evidence: AEG France — dryer C6 humidity-sensor error
- 2
Run the one discriminating check
No special tools
Procedure
Record elapsed time and load condition. Clean only the user-accessible moisture bars if the exact manual instructs it. Do not test earth with improvised tools; an electrician owns an uncertain socket.
Stop immediately for water near electricity, smoke, burning smell, abnormal heat, damaged cable or repeated breaker trips. Close the water tap when a leak is possible; sealed water, heat and mains circuits are professional-only.
Evidence: AEG France — dryer C6 humidity-sensor error
- 3
Stop at the result boundary
No special tools
Procedure
A known grounding defect belongs to the household circuit. Correct supply and clean accessible sensing surfaces with C6 returning selects moisture sensing/control; do not replace sensors before that boundary. If the same result returns after this one controlled pass, stop rather than chaining resets or cycles.
Stop immediately for water near electricity, smoke, burning smell, abnormal heat, damaged cable or repeated breaker trips. Close the water tap when a leak is possible; sealed water, heat and mains circuits are professional-only.
Evidence: AEG France — dryer C6 humidity-sensor error
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Appliances
- Brand
- AEG
- Product type
- Dryers
Known code variants
- AEG asciugatrice C6
- AEG C6 error
- AEG dryer C6
- AEG Fehler C6
- AEG secadora C6
- AEG sèche-linge C6
- AEG Trockner C6
- C6 AEG asciugatrice
- C6 AEG dryer
- C6 AEG secadora
- C6 AEG sèche-linge
- C6 AEG Trockner
- code erreur AEG C6
- error AEG C6
- errore AEG C6
What it means
AEG's official French support documents C6 on the dryer as follows: the dryer has a humidity-measurement problem; AEG also links it to cycles exceeding about 4.5 hours. The exact model manual controls compatibility; the same code on another appliance can mean something else.
Warnings and stop conditions
- Highsource verified
Stop immediately for water near electricity, smoke, burning smell, abnormal heat, damaged cable or repeated breaker trips. Close the water tap when a leak is possible; sealed water, heat and mains circuits are professional-only.
Evidence: AEG France — dryer C6 humidity-sensor error
Symptoms and causes
Probable causes · in order
- Official AEG meaningConfirmed
AEG's official French support documents C6 on the dryer as follows: the dryer has a humidity-measurement problem; AEG also links it to cycles exceeding about 4.5 hours. The exact model manual controls compatibility; the same code on another appliance can mean something else.
Evidence: AEG France — dryer C6 humidity-sensor error
- What still has to be separatedPossible
household earth, accessible sensing bars, moisture sensor circuit, harness or control
Evidence: AEG France — dryer C6 humidity-sensor error
Virtual technician
Does C6 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
AEG France — dryer C6 humidity-sensor error
AEG France · 2026 · official_doc
Was this entry useful?