Huawei inverter 2004: DC overvoltage was detected

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Wall-mounted solar photovoltaic inverter
AsurnipalCC BY-SA 4.0Image source

Risk level

Critical

Stop using the equipment and contact a professional.

Urgency

Immediate

Quick answer

Huawei alarm 2004 means DC overvoltage was detected. The deciding evidence is whether the alarm follows a string reconfiguration, cold/high-irradiance start or changed module specification. This is an installer-grade electrical alarm: do not infer or buy a component from the ID alone.

Safety first

What to do now

  • Preserve the exact alarm context

    Save a screenshot of 2004 with timestamp, cause ID, inverter model/serial, firmware, operating power, affected string/MPPT/phase and weather. Do not clear the alarm first.

  • Collect the safe discriminator

    Leave generation stopped if the alarm is active. Use only FusionSolar monitoring from a safe location; do not touch PV connectors, strings, DC switches or rooftop equipment. Record whether the alarm follows a string reconfiguration, cold/high-irradiance start or changed module specification; do not change several settings or circuits at once.

  • Respect the electrical stop boundary

    If it clears, that does not prove wiring or array configuration is safe; recurrence means keep the system off until the named DC branch is measured.

What you must never do

  • Do not attempt this professional task: Measured installer handoff for 2004

What a technician must be able to justify

A technician is coming

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured installer handoff for 2004

    What they doMeasure isolated DC input and compare every string’s cold open-circuit voltage and topology with the inverter’s exact DC limits.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Solar and energy
Brand
Huawei
Product type
Solar inverter

Known code variants

  • alarma Huawei 2004
  • alarme Huawei 2004
  • allarme Huawei 2004
  • erreur SUN2000 2004
  • error SUN2000 2004
  • errore SUN2000 2004
  • Huawei alarm 2004
  • Huawei inverter 2004
  • Huawei Wechselrichter 2004
  • inversor Huawei 2004
  • inverter Huawei 2004
  • onduleur Huawei 2004
  • SUN2000 error 2004
  • SUN2000 Fehler 2004

What it means

Huawei’s official inverter alarm reference defines 2004 as a condition in which DC overvoltage was detected. It reports a controller/protection state, not a universal failed part. Record whether the alarm follows a string reconfiguration, cold/high-irradiance start or changed module specification. The next proof is measured: Measure isolated DC input and compare every string’s cold open-circuit voltage and topology with the inverter’s exact DC limits.

Warnings and stop conditions

  • Criticalsource verified

    PV strings can remain at dangerous DC voltage in daylight even when the inverter is off. Do not disconnect, cover, probe or handle DC connectors or rooftop modules; use a qualified PV installer.

    Evidence: Huawei Inverter Alarm Reference

Sources and technical references

  1. 1

    Huawei Inverter Alarm Reference

    Huawei Digital Power · 2025 · official_doc

Sources: Huawei Inverter Alarm Referencereviewed 2026-08-23 · verified