SMA inverter event 301

Risk level
Medium
Proceed carefully and stop if the check is unclear.
Urgency
High
Quick answer
SMA defines event 301 as: The ten-minute average grid voltage is outside the permitted range, so the inverter disconnected to preserve power quality. The useful next discriminator is the ten-minute grid-voltage average and its time window. Preserve the event before any reset.
Safety first
Stop and check this first
- Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Safe checks you can perform
- Preserve the exact event context
- Collect one safe discriminator
- Respect the electrical stop point
Leave these tasks to a qualified professional
- Do not attempt this professional task: Measured handoff for SMA 301
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Measured handoff for SMA 301
What they doA qualified electrician should log phase voltages, frequency and connection-point impedance under the same export condition, then compare them with the active grid code and utility limits.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Preserve the exact event context
Save event 301, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Collect one safe discriminator
From the monitoring interface and a safe location, note whether other premises lost power and whether the event repeats at a particular export level or time. Record the ten-minute grid-voltage average and its time window; do not change multiple parameters or circuits at once.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Respect the electrical stop point
If supply to the site is abnormal, involve the grid operator; if only the inverter repeats the event, a qualified electrician must measure at the connection point.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Solar and energy
- Brand
- SMA
- Product type
- Solar inverter
Known code variants
- 301 Dauerhaft verschoben
- 301 Déplacé définitivement
- 301 Moved Permanently
- 301 Movido permanentemente
- 301 Spostato definitivamente
- código 301 Epson
- EcoTank 301 dispositivo de memoria
- EcoTank 301 memory device
- Epson 301
- Epson error code 301
- Epson ET-5800 301
- Epson ET-5805 301
- Epson L6550 301
- événement Fronius 301
- événement SMA 301
- evento Fronius 301
- evento SMA 301
- Fronius Ereignis 301
- Fronius event 301
- Fronius inverter 301
- Fronius Symo / Eco 301
- Fronius Wechselrichter 301
- HTTP 301
- HTTP status 301
- inversor Fronius 301
- inversor SMA 301
- inverter Fronius 301
- inverter SMA 301
- No hay suficiente espacio de almacenamiento para guardar los datos en el dispositivo de memoria
- onduleur Fronius 301
- onduleur SMA 301
- SMA Ereignis 301
- SMA event 301
- SMA inverter 301
- SMA Wechselrichter 301
- Sunny Tripower X 301
- There is not enough storage space available to save the data in the memory device
What it means
Official meaning: The ten-minute average grid voltage is outside the permitted range, so the inverter disconnected to preserve power quality. Decision boundary: capture the ten-minute grid-voltage average and its time window. A qualified electrician should log phase voltages, frequency and connection-point impedance under the same export condition, then compare them with the active grid code and utility limits.
Warnings and stop conditions
- Mediumsource verified
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Symptoms and causes
Probable causes · in order
- What the SMA event establishesConfirmed
The official Sunny Tripower X manual defines event 301: The ten-minute average grid voltage is outside the permitted range, so the inverter disconnected to preserve power quality.
Evidence: SMA Sunny Tripower X event messages
- The observation that changes the next branchPossible
Capture the ten-minute grid-voltage average and its time window. If supply to the site is abnormal, involve the grid operator; if only the inverter repeats the event, a qualified electrician must measure at the connection point.
Evidence: SMA Sunny Tripower X event messages
Virtual technician
Does 301 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
SMA Sunny Tripower X event messages
SMA Solar Technology AG · 2026 · official_doc
Was this entry useful?