- Solar and energy
- Solar inverter
302
SMA inverter event 302

Risk level
Low
Usually safe to check without specialist tools.
Urgency
Low
Quick answer
SMA defines event 302 as: The inverter reduced active power because grid voltage was too high. The useful next discriminator is grid voltage by phase and point-of-connection impedance. Preserve the event before any reset.
Safety first
Stop and check this first
- Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Safe checks you can perform
- Preserve the exact event context
- Collect one safe discriminator
- Respect the electrical stop point
Leave these tasks to a qualified professional
- Do not attempt this professional task: Measured handoff for SMA 302
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Measured handoff for SMA 302
What they doA qualified electrician should log phase voltages, frequency and connection-point impedance under the same export condition, then compare them with the active grid code and utility limits.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Preserve the exact event context
Save event 302, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Collect one safe discriminator
From the monitoring interface and a safe location, note whether other premises lost power and whether the event repeats at a particular export level or time. Record grid voltage by phase and point-of-connection impedance; do not change multiple parameters or circuits at once.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Respect the electrical stop point
If supply to the site is abnormal, involve the grid operator; if only the inverter repeats the event, a qualified electrician must measure at the connection point.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Solar and energy
- Brand
- SMA
- Product type
- Solar inverter
Known code variants
- 302 Encontrado
- 302 Found
- 302 Gefunden
- 302 Trouvé
- 302 Trovato
- código HTTP 302
- error HTTP 302
- événement Fronius 302
- événement SMA 302
- evento Fronius 302
- evento SMA 302
- Fronius Ereignis 302
- Fronius event 302
- Fronius inverter 302
- Fronius Symo / Eco 302
- Fronius Wechselrichter 302
- Growatt 302 sin conexión de red
- Growatt error 302
- Growatt Error: 302
- Growatt No AC Connection
- Growatt no grid connection
- HTTP 302
- HTTP error 302
- HTTP status 302
- inversor Fronius 302
- inversor SMA 302
- inverter Fronius 302
- inverter SMA 302
- onduleur Fronius 302
- onduleur SMA 302
- SMA Ereignis 302
- SMA event 302
- SMA inverter 302
- SMA Wechselrichter 302
- status code 302
- Sunny Tripower X 302
What it means
Official meaning: The inverter reduced active power because grid voltage was too high. Decision boundary: capture grid voltage by phase and point-of-connection impedance. A qualified electrician should log phase voltages, frequency and connection-point impedance under the same export condition, then compare them with the active grid code and utility limits.
Warnings and stop conditions
- Lowsource verified
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Symptoms and causes
Probable causes · in order
- What the SMA event establishesConfirmed
The official Sunny Tripower X manual defines event 302: The inverter reduced active power because grid voltage was too high.
Evidence: SMA Sunny Tripower X event messages
- The observation that changes the next branchPossible
Capture grid voltage by phase and point-of-connection impedance. If supply to the site is abnormal, involve the grid operator; if only the inverter repeats the event, a qualified electrician must measure at the connection point.
Evidence: SMA Sunny Tripower X event messages
Virtual technician
Does 302 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
SMA Sunny Tripower X event messages
SMA Solar Technology AG · 2026 · official_doc
Was this entry useful?