401
SMA inverter event 401

Risk level
Medium
Proceed carefully and stop if the check is unclear.
Urgency
High
Quick answer
SMA defines event 401 as: The inverter detected an island grid or a very large grid-frequency change and disconnected. The useful next discriminator is grid frequency, phase and the exact event timestamp. Preserve the event before any reset.
Safety first
Stop and check this first
- Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Safe checks you can perform
- Preserve the exact event context
- Collect one safe discriminator
- Respect the electrical stop point
Leave these tasks to a qualified professional
- Do not attempt this professional task: Measured handoff for SMA 401
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Measured handoff for SMA 401
What they doA qualified electrician should log phase voltages, frequency and connection-point impedance under the same export condition, then compare them with the active grid code and utility limits.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Preserve the exact event context
Save event 401, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Collect one safe discriminator
From the monitoring interface and a safe location, note whether other premises lost power and whether the event repeats at a particular export level or time. Record grid frequency, phase and the exact event timestamp; do not change multiple parameters or circuits at once.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Respect the electrical stop point
If supply to the site is abnormal, involve the grid operator; if only the inverter repeats the event, a qualified electrician must measure at the connection point.
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Solar and energy
- Brand
- SMA
- Product type
- Solar inverter
Known code variants
- 401 Nicht autorisiert
- 401 No autorizado
- 401 Non autorizzato
- 401 Unauthorized
- code erreur 401
- événement Fronius 401
- événement SMA 401
- evento Fronius 401
- evento SMA 401
- Fronius Ereignis 401
- Fronius event 401
- Fronius inverter 401
- Fronius Symo / Eco 401
- Fronius Wechselrichter 401
- HTTP 401
- HTTP status 401
- inversor Fronius 401
- inversor SMA 401
- inverter Fronius 401
- inverter SMA 401
- onduleur Fronius 401
- onduleur SMA 401
- SMA Ereignis 401
- SMA event 401
- SMA inverter 401
- SMA Wechselrichter 401
- status code 401
- Sunny Tripower X 401
What it means
Official meaning: The inverter detected an island grid or a very large grid-frequency change and disconnected. Decision boundary: capture grid frequency, phase and the exact event timestamp. A qualified electrician should log phase voltages, frequency and connection-point impedance under the same export condition, then compare them with the active grid code and utility limits.
Warnings and stop conditions
- Mediumsource verified
Do not change grid-code, voltage or frequency protection settings without installer and grid-operator authorization. Do not measure live boards yourself.
Evidence: SMA Sunny Tripower X event messages
Symptoms and causes
Probable causes · in order
- What the SMA event establishesConfirmed
The official Sunny Tripower X manual defines event 401: The inverter detected an island grid or a very large grid-frequency change and disconnected.
Evidence: SMA Sunny Tripower X event messages
- The observation that changes the next branchPossible
Capture grid frequency, phase and the exact event timestamp. If supply to the site is abnormal, involve the grid operator; if only the inverter repeats the event, a qualified electrician must measure at the connection point.
Evidence: SMA Sunny Tripower X event messages
Virtual technician
Does 401 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
SMA Sunny Tripower X event messages
SMA Solar Technology AG · 2026 · official_doc
Was this entry useful?