SMA event 7801 on solar inverter: surge arrester fault

Verified with sources4 sourcesReviewed Oct 4, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted solar photovoltaic inverter
AsurnipalCC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

Event 7801 on an SMA Sunny Tripower X warns that one or more surge arresters have tripped or are not inserted correctly, or that the telecommunication cable is not plugged in properly. A qualified person checks them and replaces tripped arresters.

Safety first

Stop and check this first

  • The surge arresters behind event 7801 sit inside the inverter, where grid and panel voltages are present: never open the unit to check them yourself.

Safe checks you can perform

  • Check inverter output in the app
  • Recall recent storms or service work
  • Keep the inverter closed even if the fix sounds simple

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Check of surge arresters and telecommunication cable
  • Do not attempt this professional task: Replacement of tripped surge arresters

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Check of surge arresters and telecommunication cable

    What they doThe qualified person safely disconnects the inverter and checks that the surge arresters and the telecommunication cable are inserted correctly.

    They must show youthe condition of each arrester and the position of the telecommunication cable.

    In writingwhich items were not seated correctly and the event list after the inspection.

  2. Replacement of tripped surge arresters

    What they doIf an arrester has tripped, the installer replaces it with a new one suitable for that inverter, as SMA's corrective measures state.

    They must show youthe arresters removed and confirmation that event 7801 no longer appears.

    In writinghow many arresters were replaced, in which positions and on what date.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Check inverter output in the app

    No special tools

    Who:
    you, from the SMA user interface or app.
    How:
    see whether the Sunny Tripower X keeps feeding power in normally while event 7801 is active; the event page does not say the inverter stops.
    Result that matters:
    knowing whether you are still generating while you wait for the qualified person.
    If output looks normal:
    book the visit anyway, because the surge arrester warning is still open.
    If output drops or other events appear:
    tell the installer when you book the inspection.
    Evidence to keep:
    a screenshot of output power and the event list with the date.

    Evidence: SMA Sunny Tripower X: Event 7801

  2. Recall recent storms or service work

    No special tools

    Who:
    you, before calling the installer.
    How:
    note whether 7801 appeared after a thunderstorm with nearby lightning or after a service visit where the inverter or its communication wiring was handled.
    Result that matters:
    helping the technician decide between a tripped arrester and something not plugged in properly.
    If there was a storm:
    mention it, as it fits with tripped arresters.
    If there was recent work on the system:
    say so too, as it points to a connector not seated correctly.
    Evidence to keep:
    the date of the storm or of the last service visit.

    Evidence: SMA Sunny Tripower X: Event 7801

  3. Keep the inverter closed even if the fix sounds simple

    No special tools

    Who:
    you, if you are tempted to look at the arresters.
    How:
    do not remove covers or plug anything in: the arresters sit inside the unit and SMA marks this event for qualified persons.
    Result that matters:
    avoiding contact with parts that may carry AC or DC voltage.
    If the installer offers a visit within days:
    wait for the visit without touching the unit.
    If the visit is delayed:
    ask them whether the inverter should stay in operation meanwhile.
    Evidence to keep:
    a note of when you called and what the installer advised.

    Evidence: SMA Sunny Tripower X: Event 7801

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Solar and energy
Brand
SMA
Product type
Solar inverter

Known code variants

  • Fallo descargador sobretensión
  • Fault overvoltage protector
  • SMA descargador de sobretensiones disparado
  • SMA event 7801
  • SMA evento 7801
  • SMA protección contra sobretensiones fallo
  • SMA Sunny Tripower X 7801
  • SMA Sunny Tripower X event 7801
  • SMA surge arrester tripped
  • SMA surge protection fault

What it means

The Sunny Tripower X online manual (STP 12-50 to 25-50, firmware 3.06.15.R or later) describes event 7801 'Fault overvoltage protector': one or more surge arresters have tripped, or one or more surge arresters or the telecommunication cable are not inserted correctly. SMA addresses the corrective measures to qualified persons: make sure everything is inserted correctly and replace tripped arresters with new ones. The message on its own does not confirm which arrester is affected or whether a real surge occurred, and other models or firmware may present it differently.

Warnings and stop conditions

  • Highsource verified

    The surge arresters behind event 7801 sit inside the inverter, where grid and panel voltages are present: never open the unit to check them yourself.

    Evidence: SMA Sunny Tripower X: Event 7801

Symptoms and causes

Probable causes · in order

  • Tripped surge arrestersCommon

    SMA explains that event 7801 appears when one or more of the inverter's surge arresters have tripped and need to be replaced with new ones.

    Evidence: SMA Sunny Tripower X: Event 7801

  • Surge arrester not inserted correctlyPossible

    The manual allows for one or more surge arresters not being seated correctly, for example after earlier work on the unit.

    Evidence: SMA Sunny Tripower X: Event 7801

  • Telecommunication cable not inserted correctlyPossible

    SMA lists a telecommunication cable that is not plugged in correctly among the causes of event 7801.

    Evidence: SMA Sunny Tripower X: Event 7801

Virtual technician

Does 7801 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

  1. 1

    SMA Sunny Tripower X: Event 7801

    SMA Solar Technology AG · 2026 · official_doc

  2. 2

    SMA Sunny Tripower X: evento 7801

    SMA Solar Technology AG · 2026 · official_doc

  3. 3

    SMA Sunny Tripower X: validity

    SMA Solar Technology AG · 2026 · official_doc

  4. 4

    SMA Sunny Tripower X: área de validez

    SMA Solar Technology AG · 2026 · official_doc

Sources: SMA Sunny Tripower X: Event 7801 · SMA Sunny Tripower X: evento 7801 · SMA Sunny Tripower X: validity · SMA Sunny Tripower X: área de validezreviewed 2026-10-04 · verified

Was this entry useful?