Quick answer

The message Panel refresh did not finish on a Sony Bravia OLED TV means the cycle stopped because the TV was turned on, unplugged from AC power, or outside 10 °C to 40 °C. Start the procedure again from Settings and allow up to an hour.

Safety first

Stop and check this first

  • Perform a manual [Panel refresh] only when image retention is particularly noticeable, and avoid running it more than once a year because Sony states it may affect the usable life of the panel.
  • Do not unplug the AC power cord or turn the TV on while panel refresh is running (it may take up to an hour depending on your model), and avoid displaying clocks or bright static colours for long periods.

Safe checks you can perform

  • Verify AC power connection and 10 °C to 40 °C room temperature
  • Start Panel refresh again from Expert panel settings
  • Keep Pixel shift enabled and turn off via remote daily

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Authorized Sony service inspection of the OLED panel
  • Do not attempt this professional task: OLED refresh review with official Sony support

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Authorized Sony service inspection of the OLED panel

    What they doWhen the panel refresh cannot complete under valid room and power conditions or noticeable retention persists after a completed cycle, an authorized Sony technician inspects the TV without any user disassembly.

    They must show youthe diagnostic check of the OLED panel status and verification that standby power stays active during the refresh window.

    In writingwhat tests were performed, the firmware version verified, and whether any panel or power component replacement was carried out.

  2. OLED refresh review with official Sony support

    What they doIf [Panel refresh did not finish] keeps appearing even when the TV stays off on continuous AC power between 10 °C and 40 °C, Sony support reviews the symptom and cycle history for your OLED model.

    They must show youthe model and serial label on the TV, the current software version, and a photo of the [Panel refresh did not finish] message.

    In writingthe Sony support case number, whether a completed panel refresh was logged, and the official guidance for your panel.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Verify AC power connection and 10 °C to 40 °C room temperature

    No special tools

    Who:
    you, next to the Sony OLED TV before restarting the procedure.
    How:
    confirm that the AC power cord (mains lead) is firmly plugged into a live outlet that will not be switched off, and check that the room temperature stays between 10 °C and 40 °C for the full hour the cycle may take.
    Result that matters:
    ruling out power interruptions and out-of-range room temperatures before launching another refresh.
    If the room is colder than 10 °C or warmer than 40 °C:
    wait until ambient temperature stays within the 10 °C to 40 °C window.
    If both AC power and room temperature are stable:
    start the panel refresh again from the beginning without turning the TV back on early.
    Evidence to keep:
    photo of the on-screen message together with the room temperature and time.

    Evidence: Sony BRAVIA Help Guide: The message [Panel refresh did not finish] is displayed (OLED models)

  2. Start Panel refresh again from Expert panel settings

    No special tools

    Who:
    you, using the Sony Bravia remote control.
    How:
    press the (Quick Settings) button on the remote control, then select [Settings] > [Display & Sound] > [Expert panel settings] > [Panel refresh]. Leave the TV off and plugged in until the routine finishes, which can take up to an hour depending on your model.
    Result that matters:
    completing the full panel refresh cycle so the incomplete message clears.
    If the refresh completes and the message no longer appears:
    keep [Pixel shift] enabled for normal viewing.
    If the message returns even though nobody touched the power cord or remote in a 10 °C to 40 °C room:
    contact Sony support with your model details.
    Evidence to keep:
    start time and completion time of the panel refresh attempt.

    Evidence: Sony BRAVIA Help Guide: The message [Panel refresh did not finish] is displayed (OLED models) · Sony BRAVIA Help Guide: You are concerned about an image retention (OLED models)

  3. Keep Pixel shift enabled and turn off via remote daily

    No special tools

    Who:
    you, inside the OLED display settings menu.
    How:
    under [Settings] > [Display & Sound] > [Expert panel settings], verify that [Pixel shift] is enabled and turn off the TV with the remote control or TV power button for more than four hours daily while leaving the AC cord plugged in.
    Result that matters:
    preventing image retention in daily use without running extra manual panel refreshes.
    If retention fades with daily standby and pixel shift:
    avoid running manual panel refresh again.
    If image retention remains prominent after one completed refresh:
    consult Sony authorized service rather than repeating the manual cycle.
    Evidence to keep:
    photo of the [Expert panel settings] screen showing [Pixel shift] enabled.

    Evidence: Sony BRAVIA Help Guide: You are concerned about an image retention (OLED models)

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
TVs
Brand
Sony
Product type
Smart TV

Known code variants

  • Actualización del panel incompleta Sony Bravia
  • Bravia panel refresh incomplete
  • Error actualización del panel Sony OLED
  • La actualización del panel no ha finalizado
  • Panel refresh did not finish
  • Sony La actualización del panel no ha finalizado
  • Sony OLED panel refresh did not finish
  • The message Panel refresh did not finish is displayed

What it means

In the 2023 Sony Bravia Google TV Help Guide (kaep1, manual 5-057-647-12(1)), which applies to models equipped with an OLED panel, Sony states that [Panel refresh did not finish] appears when the panel refresh routine is interrupted before completion. The TV provides [Pixel shift] and [Panel refresh] to reduce image retention, which Sony notes is not a malfunction. Menu paths and cycle duration vary across models, and this message alone never proves that the OLED panel or any hardware part is faulty.

Warnings and stop conditions

  • Mediumeditorial warning

    Perform a manual [Panel refresh] only when image retention is particularly noticeable, and avoid running it more than once a year because Sony states it may affect the usable life of the panel.

    Evidence: Sony BRAVIA Help Guide: You are concerned about an image retention (OLED models)

  • Loweditorial warning

    Do not unplug the AC power cord or turn the TV on while panel refresh is running (it may take up to an hour depending on your model), and avoid displaying clocks or bright static colours for long periods.

    Evidence: Sony BRAVIA Help Guide: The message [Panel refresh did not finish] is displayed (OLED models) · Sony BRAVIA Help Guide: You are concerned about an image retention (OLED models)

Symptoms and causes

Probable causes · in order

  • TV turned on or AC power cord unplugged during refreshCommon

    Sony states that if the TV is switched on or the AC power cord (mains lead) is unplugged while panel refresh is running, the process does not finish and displays this message.

    Evidence: Sony BRAVIA Help Guide: The message [Panel refresh did not finish] is displayed (OLED models)

  • Room temperature outside the 10 °C to 40 °C rangePossible

    According to the Help Guide, if the ambient temperature drops below 10 °C or rises above 40 °C during the panel refresh, the cycle cannot complete and triggers this alert.

    Evidence: Sony BRAVIA Help Guide: The message [Panel refresh did not finish] is displayed (OLED models)

  • Noticeable image retention from static bright graphicsPossible

    Sony notes that displaying the same image repeatedly, especially clocks and bright colours, can cause image retention that prompts a manual panel refresh.

    Evidence: Sony BRAVIA Help Guide: You are concerned about an image retention (OLED models)

Virtual technician

Does Panel refresh did not finish still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Sony BRAVIA Help Guide: The message [Panel refresh did not finish] is displayed (OLED models) · Guía de ayuda Sony BRAVIA: Aparece el mensaje [La actualización del panel no ha finalizado] (modelos OLED) · Sony BRAVIA Help Guide: You are concerned about an image retention (OLED models) · Guía de ayuda Sony BRAVIA: Le preocupa que aparezca retención de imagen (modelos OLED)reviewed 2026-10-18 · verified

Was this entry useful?