Independent technical referenceOfficial site
  • Heat pumps
  • Air-to-water heat pump

H70

Panasonic H70 on an Aquarea heat pump: backup heater overload protection

Verified with sources2 sourcesReviewed Oct 3, 2026
Technician coming? See the 2 steps they must show you
Air-to-water heat pump outdoor unit next to a house
Mueller felixCC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

On Aquarea units, H70 means the electric backup heater overload protection has tripped or its supply is missing. You can reset it from the controller, but Panasonic says to contact the installer for a full reset.

Safety first

Stop and check this first

  • Panasonic states that service must be carried out by qualified personnel only and that you must not put fingers into the unit, as rotating parts may cause injury. When a code shows, turn the unit off and give the code to an authorised dealer.

Safe checks you can perform

  • Reset from the controller
  • Backup heater supply breaker
  • Voltage at power supply 2 and thermostats

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measure the supply before the heater
  • Do not attempt this professional task: Thermostat reset with venting

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measure the supply before the heater

    What they doThe installer measures voltage at power supply 2 before touching the heater or its thermostats.

    They must show youthe voltage measured at power supply 2.

    In writingwhether the fault was supply or thermostat and what was corrected.

  2. Thermostat reset with venting

    What they doIf a thermostat tripped, the installer resets it and checks no air remains around the heater.

    They must show youthe venting done and the heater running without H70.

    In writingthe thermostat reset and the test with electric backup running.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Reset from the controller

    No special tools

    Who:
    you.
    How:
    reset the code from the controller as Panasonic's user guide describes.
    Result that matters:
    Panasonic warns the system will appear to run normally, but a full reset by the installer is needed.
    If the code clears:
    the electric backup is still unverified; tell the installer anyway.
    If it returns as soon as backup is called:
    the protection is still open or the supply is missing.
    Evidence to keep:
    a photo of the code and a note of when backup was called, for example on very cold days.

    Evidence: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series · Panasonic Aquarea installation guide 1.2, Monobloc solutions H and J generation

  2. Backup heater supply breaker

    No special tools

    Who:
    you, only looking at the consumer unit.
    How:
    check whether the breaker feeding the heat pump backup heater is off.
    Result that matters:
    Panasonic says H70 also shows when power supply 2 is missing.
    If it is off:
    switch it on once; if it trips again, leave it and call an electrician or the installer.
    If it is on:
    a visible cut is ruled out; the installer measures the voltage.
    Evidence to keep:
    a photo of the consumer unit.

    Evidence: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series · Panasonic Aquarea installation guide 1.2, Monobloc solutions H and J generation

  3. Voltage at power supply 2 and thermostats

    Tools required

    Who:
    the installer.
    How:
    they measure the voltage at power supply 2; if correct, they check whether a heater thermostat has tripped, reset it and make sure the heater is free from air.
    Result that matters:
    voltage present or absent and the state of each thermostat.
    If the voltage is wrong:
    the supply is the cause; the electrical circuit is corrected.
    If voltage is correct and a thermostat is open:
    overheat is confirmed; the heater must be vented before closing the job.
    Evidence to keep:
    a job sheet with the measured voltage and the thermostat reset.

    Mains voltage on the backup heater. Installer or electrician only, with the supply isolated.

    Evidence: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series · Panasonic Aquarea installation guide 1.2, Monobloc solutions H and J generation

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Heat pumps
Brand
Panasonic
Product type
Air-to-water heat pump

Known code variants

  • Aquarea H70
  • Panasonic Aquarea H70
  • Panasonic heat pump H70

What it means

Panasonic explains that the internal backup heater has overheat thermostats; if one trips and becomes open circuit, H70 occurs. It also shows when power supply 2, which feeds the heater, is missing. It only appears when the backup heater is activated. The installer flowchart separates incorrect voltage at power supply 2 from a tripped thermostat, which is reset while making sure the heater is free from air. The code does not prove the heater is broken.

Warnings and stop conditions

  • Mediumsource verified

    Panasonic states that service must be carried out by qualified personnel only and that you must not put fingers into the unit, as rotating parts may cause injury. When a code shows, turn the unit off and give the code to an authorised dealer.

    Evidence: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series

Symptoms and causes

Probable causes · in order

  • Power supply 2 missingCommon

    If the heater supply breaker or cable is off, H70 shows when backup is called. Measuring voltage at that supply separates it.

    Evidence: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series · Panasonic Aquarea installation guide 1.2, Monobloc solutions H and J generation

  • Overload thermostat trippedCommon

    One of the heater's internal thermostats opened on overheat. Panasonic says to reset it and make sure the heater is free from air.

    Evidence: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series · Panasonic Aquarea installation guide 1.2, Monobloc solutions H and J generation

  • Air around the heaterPossible

    With air around the heater it overheats and trips the thermostat. It is the step Panasonic adds after the reset.

    Evidence: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series · Panasonic Aquarea installation guide 1.2, Monobloc solutions H and J generation

Virtual technician

Does H70 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

Sources: Panasonic Aquarea user guide for Bi-Bloc, Monobloc and All in One, C, D and E series · Panasonic Aquarea installation guide 1.2, Monobloc solutions H and J generationreviewed 2026-10-03 · verified

Was this entry useful?