PEN Fault

myenergi zappi PEN Fault (Fault code 29) on an EV charger: loss of PEN protection tripped

Verified with sources2 sourcesReviewed Oct 4, 2026
Technician coming? See the 3 steps they must show you
Wall-mounted EV charger (wallbox) with charging cable
Solomon203CC BY-SA 4.0Image source

Risk level

Critical

Stop using the equipment and contact a professional.

Urgency

High

Quick answer

The zappi internal protection against loss of the supply PEN conductor has tripped. Unplug the car, do not touch it while the alert stays, and ask an electrician to check the supply.

Safety first

What to do now

  • Unplug without forcing a reset

    Who: you, no tools. How: unplug the car. myenergi says to make sure the fault has been removed before pressing and holding the reset button. Result that matters: not resetting while it is unknown whether the fault persists. If you cannot confirm the fault was removed: do not reset; call an electrician. If an electrician confirms the supply is sound: a reset per the manual is then appropriate. Evidence to keep: photo of the PEN Fault screen, date and time.

  • Other electrical symptoms in the home

    Who: you, observing only. How: notice whether lights flicker, appliances switch off or RCDs trip at the same time. Result that matters: whether the problem affects more than the charger circuit. If other circuits show symptoms: points to the supply; tell the electrician and the network operator. If only the zappi is affected: does not rule out the supply but narrows the inspection. Evidence to keep: list of symptoms with times.

  • Supply and neutral measurement

    Who: qualified electrician. How: measure line-neutral, neutral-earth and line-earth voltages at the origin and at the charger, and earth loop impedance. Result that matters: signs of a faulty neutral or PEN. If readings show a defect upstream of the consumer unit: confirms a supply problem for the network operator. If readings are correct and stable: rules out an active open PEN at that time. Evidence to keep: report with every reading and where it was taken.

What you must never do

  • Do not attempt this professional task: Earth loop impedance and earthing system
  • Do not attempt this professional task: RCD test and report to the network operator
  • Do not attempt this professional task: Voltage measurement at the origin and the charger

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Earth loop impedance and earthing system

    What they doMeasures earth loop impedance and confirms the earthing arrangement (for example TN-C-S).

    They must show youthe system identified and the impedance reading.

    In writingvalue against the applicable limit and the conclusion.

  2. RCD test and report to the network operator

    What they doTests the circuit RCD or RCBO and, if the defect is in the network, reports the measured evidence to the network operator.

    They must show youthe measured trip time and the report for the network operator.

    In writingdate reported and any incident reference given.

  3. Voltage measurement at the origin and the charger

    What they doThe electrician measures line-neutral, neutral-earth and line-earth with an installation tester at the main consumer unit and at the zappi terminals.

    They must show youreadings at both points.

    In writingvalues, measuring points and whether the defect is in the service cable or the internal installation.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
EV charging
Brand
myenergi
Product type
EV charger

Known code variants

  • zappi error 29 PEN
  • zappi fallo PEN
  • zappi fault code 29
  • zappi open PEN fault
  • zappi PEN Fault
  • Zaptec fallo PEN
  • Zaptec Go abnormal supply voltage
  • Zaptec Go fallo de PEN
  • Zaptec Go PEN fault detected
  • Zaptec Go protección PEN tensión anómala
  • Zaptec Go UK luz roja PEN
  • Zaptec Go UK red light PEN
  • Zaptec neutro abierto
  • Zaptec open PEN fault
  • Zaptec PEN fault protection tripped

What it means

myenergi defines Fault code 29 as the internal protection against loss of the supply PEN conductor having tripped. That fault only occurs on TN systems, where earth and neutral are combined in the cable feeding the property. The ZAPPI-2Hxxx-G (UK) version includes this protection. The code says the zappi saw the condition, not where the wiring fault is or whether it is still present.

Warnings and stop conditions

  • Criticaleditorial warning

    With PEN Fault active, do not touch the plugged-in car or the charger beyond unplugging the cable. A faulty PEN can make metal parts live.

    Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023 · zappi versions and "PEN Fault" detection

  • Highsource verified

    Do not reset until the fault has been removed, as myenergi says. Repeated resets do not prove the supply is safe.

    Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023 · zappi versions and "PEN Fault" detection