myenergi zappi SelfTest Failed (Fault code 27) on an EV charger: protection self test failed

Risk level
High
Professional inspection is recommended.
Urgency
High
Quick answer
Before charging, the zappi could not test its built-in protection or it failed the test. Unplug the car and press and hold the reset button; if it returns, stop using it.
Safety first
Stop and check this first
- If SelfTest Failed persists, myenergi says to stop using the zappi. Do not reset it in a loop to force a charge without verified protection.
Safe checks you can perform
- Unplug and reset with the button
- Repeats across sessions
- Built-in protection diagnosis
Leave these tasks to a qualified professional
- Do not attempt this professional task: RCD trip test on the supply circuit
- Do not attempt this professional task: Insulation and supply voltage measurement
- Do not attempt this professional task: Documented repair or replacement
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
RCD trip test on the supply circuit
What they doThe electrician tests the RCD or RCBO feeding the zappi with an RCD tester.
They must show youmeasured trip times.
In writingdevice type, test currents and result against the specification.
Insulation and supply voltage measurement
What they doMeasures insulation resistance on the charger circuit with the unit isolated and supply voltage at its terminals.
They must show youinsulation and voltage readings against your wiring rules.
In writingmeasured values and whether the circuit is ruled out.
Documented repair or replacement
What they doIf the technician confirms an internal fault, they repair or replace the unit and run a full charge.
They must show youa charge session that passes the self test with no alert.
In writingpart or unit replaced with reference and serial number, reason and date.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Unplug and reset with the button
- Who:
- you, no tools.
- How:
- unplug the car and press and hold the zappi reset button, as the manual says.
- Result that matters:
- whether the next charge attempt passes the self test.
- If it charges and the alert does not return:
- points to a one-off failure; note it.
- If SelfTest Failed returns:
- rules out a transient and stop using the zappi, as myenergi says.
- Evidence to keep:
- photo of the screen and time of each occurrence.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Repeats across sessions
- Who:
- you, no tools.
- How:
- note for a few days whether the alert appears on plug-in, mid-session or after a power cut.
- Result that matters:
- the pattern of occurrence.
- If it only appears after a power cut or work at the consumer unit:
- tell the technician; it narrows the condition.
- If it appears on every attempt:
- supports internal protection not responding.
- Evidence to keep:
- list of dates and circumstances.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Built-in protection diagnosis
- Who:
- myenergi service technician or authorised installer.
- How:
- test the zappi with diagnostic tools and inspect the circuit feeding it.
- Result that matters:
- whether internal protection passes under controlled conditions.
- If internal protection does not respond:
- confirms a unit fault.
- If the unit passes:
- look for the cause in the supply or installation.
- Evidence to keep:
- diagnostic report with the test result.
Internal diagnosis means opening or working on a unit at mains voltage. Do not do it yourself.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- EV charging
- Brand
- myenergi
- Product type
- EV charger
Known code variants
- zappi error 27 autotest
- zappi fault code 27
- zappi self test failed
- zappi SelfTest Failed
What it means
myenergi defines Fault code 27 as the built-in protection devices could not be tested or failed the test before a charge. The zappi runs that self test before each session so it never charges without protection. It can come from a transient condition during the test or from internal protection that no longer responds. The code does not identify which component failed.
Warnings and stop conditions
- Highsource verified
If SelfTest Failed persists, myenergi says to stop using the zappi. Do not reset it in a loop to force a charge without verified protection.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Symptoms and causes
Probable causes · in order
- Transient condition during the self testPossible
If after unplugging and resetting the zappi charges normally and the alert does not return, the test failed as a one-off.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
- Internal protection failing the testPossible
If the alert returns on every attempt, the built-in protection is not responding correctly. Only the service technician can confirm it.
Evidence: zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
Virtual technician
Does SelfTest Failed still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
zappi eco-smart EV charge point User Manual Rev 2.2 July 2023
myenergi · 2023 · manual