Fronius state 112 on solar inverter: RCMU error explained

Risk level
Medium
Proceed carefully and stop if the check is unclear.
Urgency
Medium
Quick answer
State 112 on a Fronius Symo or Eco means an RCMU (residual current monitoring) error. The inverter disconnects from the grid and tries again; if the code keeps coming back or stays on, call your installer and leave the wiring alone.
Safety first
Stop and check this first
- With an RCMU error, do not open the inverter or touch DC cables and connectors: the solar modules keep producing voltage as long as there is daylight.
Safe checks you can perform
- See whether state 112 clears on its own
- Log every return of code 112
- Use the USB log book if it is already set up
Leave these tasks to a qualified professional
- Do not attempt this professional task: Inspection of the inverter AC connection
- Do not attempt this professional task: Diagnosis by a Fronius-trained technician
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Inspection of the inverter AC connection
What they doThe installer checks the Fronius grid connections, the first remedy in the class 1 table, and measures the voltage at the AC terminals.
They must show youthe grid voltage and frequency measured at the inverter terminals and the condition of the terminal connections.
In writingthe measured values, which terminals were checked or retightened, and the date.
Diagnosis by a Fronius-trained technician
What they doIf code 112 does not clear, a Fronius-trained service technician reviews the message history, the firmware version and the country setup of the inverter.
They must show youthe STATE code history, the firmware version and the country setup.
In writingthe tests carried out, their results and any part replaced.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
See whether state 112 clears on its own
- Who:
- you, reading the Fronius display without opening anything.
- How:
- watch the orange status LED, which is lit while a STATE code is shown, and check whether the green operating LED returns with normal feed-in afterwards.
- Result that matters:
- knowing whether this was a passing grid event or a fault that persists.
- If the green LED returns and the inverter feeds in normally:
- Fronius says a brief code followed by normal operation is not a fault.
- If 112 stays on the display or returns several times:
- note it and call the installer, as the class 1 table advises.
- Evidence to keep:
- a photo of the display showing the code and the time you saw it.
Evidence: Fronius Symo / Eco status diagnostics
Log every return of code 112
- Who:
- you, over several days.
- How:
- write down date, time and weather whenever state 112 appears, and whether it coincides with power cuts, storms or other devices tripping in the house.
- Result that matters:
- a record that helps the installer see whether the RCMU error follows a pattern.
- If it shows up only once in a while and feed-in resumes:
- keep the log in case it repeats.
- If it appears daily or at the same time:
- share the log when you book the inspection.
- Evidence to keep:
- a list of occurrences with date, time and circumstances.
Evidence: Fronius Symo / Eco status diagnostics
Use the USB log book if it is already set up
- Who:
- you, only if the installer has enabled this function in the Setup menu.
- How:
- the Fronius Symo can save all error messages to a USB flash drive; if this is already active, hand that drive to the technician instead of changing settings you do not know.
- Result that matters:
- the technician gets the full message history, not just what you happened to see on screen.
- If the function is active:
- pass the file to the installer before the visit.
- If you are not sure whether it is active:
- leave the settings alone and ask the installer to check.
- Evidence to keep:
- the log file, or a note that none exists.
Evidence: Fronius Symo / Eco status diagnostics
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Solar and energy
- Brand
- Fronius
- Product type
- Solar inverter
Known code variants
- cargador Wallbox 112
- caricatore Wallbox 112
- chargeur Wallbox 112
- code Wallbox 112
- codice Wallbox 112
- código Wallbox 112
- erreur Wallbox 112
- Error de monitorización de corriente de falta
- error RCMU inversor Fronius
- error Wallbox 112
- errore Wallbox 112
- Fronius código 112 RCMU
- Fronius Eco RCMU error
- Fronius estado 112
- Fronius State 112
- Fronius state code 112
- Fronius Symo error 112
- RCMU error
- Wallbox app code 112
- Wallbox charger 112
- Wallbox error 112
- Wallbox Fehler 112
- Wallbox Fehlercode 112
- Wallbox Ladegerät 112
What it means
In the Fronius Symo / Fronius Eco operating instructions (version 044-17072025), code 112 is listed in class 1 as 'RCMU error'. Fronius explains that class 1 codes generally appear only momentarily and are caused by the public grid: the inverter disconnects, monitors the grid for the stipulated period and resumes feed-in if no further problem is found. The technical data list the RCMU as an integrated protection device. Seeing 112 does not by itself prove that the RCMU or the inverter is faulty, and other models or firmware may behave differently.
Warnings and stop conditions
- Highsource verified
With an RCMU error, do not open the inverter or touch DC cables and connectors: the solar modules keep producing voltage as long as there is daylight.
Evidence: Fronius Symo / Eco status diagnostics
Symptoms and causes
Probable causes · in order
- Short disturbance on the public gridCommon
Fronius attributes class 1 status codes, the group that includes 112, to the public grid and says they generally arise only momentarily.
Evidence: Fronius Symo / Eco status diagnostics
- Problem with the grid connectionsPossible
For class 1 codes the Fronius table suggests checking the grid connections, which points to the AC side of the installation as the place to inspect.
Evidence: Fronius Symo / Eco status diagnostics
- Brief control response of the inverterPossible
The manual notes that a code shown only briefly can come from the inverter's own control response; if it then keeps working normally, there was no fault.
Evidence: Fronius Symo / Eco status diagnostics
Virtual technician
Does 112 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
Fronius Symo / Eco status diagnostics
Fronius International GmbH · 2025 · official_doc
- 2
Fronius Symo / Eco: diagnóstico de estado
Fronius International GmbH · 2025 · official_doc
Was this entry useful?