302

Fronius inverter event 302

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Wall-mounted solar photovoltaic inverter
AsurnipalCC BY-SA 4.0Image source

Risk level

High

Professional inspection is recommended.

Urgency

Immediate

Quick answer

Fronius defines event 302 as: The inverter detected DC overcurrent and returned to its startup routine. The useful next discriminator is DC current by MPPT/string, irradiance and event sequence. Preserve the event before any reset.

Safety first

Stop and check this first

  • The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.

Safe checks you can perform

  • Preserve the exact event context
  • Collect one safe discriminator
  • Respect the electrical stop point

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measured handoff for Fronius 302

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured handoff for Fronius 302

    What they doExport diagnostics, confirm firmware and event sequence, then test the named internal monitoring path through Fronius service procedures before considering hardware replacement.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Preserve the exact event context

    No special tools

    Save event 302, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.

    The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.

    Evidence: Fronius Symo / Eco status diagnostics

  2. Collect one safe discriminator

    No special tools

    Record the full event sequence, firmware and LED state. Do not open the inverter or repeat restarts; export diagnostics if the UI allows it. Record DC current by MPPT/string, irradiance and event sequence; do not change multiple parameters or circuits at once.

    The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.

    Evidence: Fronius Symo / Eco status diagnostics

  3. Respect the electrical stop point

    No special tools

    If the red LED or event returns, stop cycling power and send the diagnostic package to Fronius or a qualified installer.

    The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.

    Evidence: Fronius Symo / Eco status diagnostics

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Solar and energy
Brand
Fronius
Product type
Solar inverter

Known code variants

  • 302 Encontrado
  • 302 Found
  • 302 Gefunden
  • 302 Trouvé
  • 302 Trovato
  • código HTTP 302
  • error HTTP 302
  • événement Fronius 302
  • événement SMA 302
  • evento Fronius 302
  • evento SMA 302
  • Fronius Ereignis 302
  • Fronius event 302
  • Fronius inverter 302
  • Fronius Symo / Eco 302
  • Fronius Wechselrichter 302
  • Growatt 302 sin conexión de red
  • Growatt error 302
  • Growatt Error: 302
  • Growatt No AC Connection
  • Growatt no grid connection
  • HTTP 302
  • HTTP error 302
  • HTTP status 302
  • inversor Fronius 302
  • inversor SMA 302
  • inverter Fronius 302
  • inverter SMA 302
  • onduleur Fronius 302
  • onduleur SMA 302
  • SMA Ereignis 302
  • SMA event 302
  • SMA inverter 302
  • SMA Wechselrichter 302
  • status code 302
  • Sunny Tripower X 302

What it means

Official meaning: The inverter detected DC overcurrent and returned to its startup routine. Decision boundary: capture DC current by MPPT/string, irradiance and event sequence. Export diagnostics, confirm firmware and event sequence, then test the named internal monitoring path through Fronius service procedures before considering hardware replacement.

Warnings and stop conditions

  • Highsource verified

    The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.

    Evidence: Fronius Symo / Eco status diagnostics

Symptoms and causes

Probable causes · in order

  • What the Fronius event establishesConfirmed

    The official Fronius Symo / Eco manual defines event 302: The inverter detected DC overcurrent and returned to its startup routine.

    Evidence: Fronius Symo / Eco status diagnostics

  • The observation that changes the next branchPossible

    Capture DC current by MPPT/string, irradiance and event sequence. If the red LED or event returns, stop cycling power and send the diagnostic package to Fronius or a qualified installer.

    Evidence: Fronius Symo / Eco status diagnostics

Virtual technician

Does 302 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references