- Solar and energy
- Solar inverter
305
Fronius inverter event 305

Risk level
Medium
Proceed carefully and stop if the check is unclear.
Urgency
High
Quick answer
Fronius defines event 305 as: No power is fed in despite the relay being closed. The useful next discriminator is relay state, AC phase values and events immediately before the stop. Preserve the event before any reset.
Safety first
Stop and check this first
- The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.
Safe checks you can perform
- Preserve the exact event context
- Collect one safe discriminator
- Respect the electrical stop point
Leave these tasks to a qualified professional
- Do not attempt this professional task: Measured handoff for Fronius 305
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Measured handoff for Fronius 305
What they doExport diagnostics, confirm firmware and event sequence, then test the named internal monitoring path through Fronius service procedures before considering hardware replacement.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Preserve the exact event context
Save event 305, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.
The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.
Evidence: Fronius Symo / Eco status diagnostics
Collect one safe discriminator
Record the full event sequence, firmware and LED state. Do not open the inverter or repeat restarts; export diagnostics if the UI allows it. Record relay state, AC phase values and events immediately before the stop; do not change multiple parameters or circuits at once.
The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.
Evidence: Fronius Symo / Eco status diagnostics
Respect the electrical stop point
If the red LED or event returns, stop cycling power and send the diagnostic package to Fronius or a qualified installer.
The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.
Evidence: Fronius Symo / Eco status diagnostics
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Solar and energy
- Brand
- Fronius
- Product type
- Solar inverter
Known code variants
- événement Fronius 305
- evento Fronius 305
- Fronius Ereignis 305
- Fronius event 305
- Fronius inverter 305
- Fronius Symo / Eco 305
- Fronius Wechselrichter 305
- inversor Fronius 305
- inverter Fronius 305
- onduleur Fronius 305
What it means
Official meaning: No power is fed in despite the relay being closed. Decision boundary: capture relay state, AC phase values and events immediately before the stop. Export diagnostics, confirm firmware and event sequence, then test the named internal monitoring path through Fronius service procedures before considering hardware replacement.
Warnings and stop conditions
- Mediumsource verified
The inverter contains hazardous stored and live energy. Do not open it or bypass internal protection.
Evidence: Fronius Symo / Eco status diagnostics
Symptoms and causes
Probable causes · in order
- What the Fronius event establishesConfirmed
The official Fronius Symo / Eco manual defines event 305: No power is fed in despite the relay being closed.
Evidence: Fronius Symo / Eco status diagnostics
- The observation that changes the next branchPossible
Capture relay state, AC phase values and events immediately before the stop. If the red LED or event returns, stop cycling power and send the diagnostic package to Fronius or a qualified installer.
Evidence: Fronius Symo / Eco status diagnostics
Virtual technician
Does 305 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
Fronius Symo / Eco status diagnostics
Fronius International GmbH · 2025 · official_doc
Was this entry useful?