Fronius inverter event 306

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Wall-mounted solar photovoltaic inverter
AsurnipalCC BY-SA 4.0Image source

Risk level

Low

Usually safe to check without specialist tools.

Urgency

Low

Quick answer

Fronius defines event 306 as: PV output is too low for grid feed-in; this can be a normal low-irradiance state. The useful next discriminator is irradiance, DC voltage and whether feed-in resumes when conditions change. Preserve the event before any reset.

Safety first

Stop and check this first

  • Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.

Safe checks you can perform

  • Preserve the exact event context
  • Collect one safe discriminator
  • Respect the electrical stop point

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measured handoff for Fronius 306

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured handoff for Fronius 306

    What they doCompare the event timeline with DC start thresholds, insulation-test state, irradiance and temperature; use those values to decide whether this is expected state or a blocked input.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Preserve the exact event context

    No special tools

    Save event 306, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.

    Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.

    Evidence: Fronius Symo / Eco status diagnostics

  2. Collect one safe discriminator

    No special tools

    Read monitoring only. Compare the event start/end with daylight, DC voltage, temperature and whether feed-in resumes without intervention. Record irradiance, DC voltage and whether feed-in resumes when conditions change; do not change multiple parameters or circuits at once.

    Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.

    Evidence: Fronius Symo / Eco status diagnostics

  3. Respect the electrical stop point

    No special tools

    A single documented self-test or cold/start wait can be observed. If the stated condition clears but feed-in does not resume, escalate with the timeline.

    Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.

    Evidence: Fronius Symo / Eco status diagnostics

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Solar and energy
Brand
Fronius
Product type
Solar inverter

Known code variants

  • événement Fronius 306
  • evento Fronius 306
  • Fronius Ereignis 306
  • Fronius event 306
  • Fronius inverter 306
  • Fronius Symo / Eco 306
  • Fronius Wechselrichter 306
  • inversor Fronius 306
  • inverter Fronius 306
  • onduleur Fronius 306

What it means

Official meaning: PV output is too low for grid feed-in; this can be a normal low-irradiance state. Decision boundary: capture irradiance, DC voltage and whether feed-in resumes when conditions change. Compare the event timeline with DC start thresholds, insulation-test state, irradiance and temperature; use those values to decide whether this is expected state or a blocked input.

Warnings and stop conditions

  • Lowsource verified

    Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.

    Evidence: Fronius Symo / Eco status diagnostics

Symptoms and causes

Probable causes · in order

  • What the Fronius event establishesConfirmed

    The official Fronius Symo / Eco manual defines event 306: PV output is too low for grid feed-in; this can be a normal low-irradiance state.

    Evidence: Fronius Symo / Eco status diagnostics

  • The observation that changes the next branchPossible

    Capture irradiance, DC voltage and whether feed-in resumes when conditions change. A single documented self-test or cold/start wait can be observed. If the stated condition clears but feed-in does not resume, escalate with the timeline.

    Evidence: Fronius Symo / Eco status diagnostics

Virtual technician

Does 306 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

  1. 1

    Fronius Symo / Eco status diagnostics

    Fronius International GmbH · 2025 · official_doc

Sources: Fronius Symo / Eco status diagnosticsreviewed 2026-08-23 · verified

Was this entry useful?