- Solar and energy
- Solar inverter
306
Fronius inverter event 306

Risk level
Low
Usually safe to check without specialist tools.
Urgency
Low
Quick answer
Fronius defines event 306 as: PV output is too low for grid feed-in; this can be a normal low-irradiance state. The useful next discriminator is irradiance, DC voltage and whether feed-in resumes when conditions change. Preserve the event before any reset.
Safety first
Stop and check this first
- Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.
Safe checks you can perform
- Preserve the exact event context
- Collect one safe discriminator
- Respect the electrical stop point
Leave these tasks to a qualified professional
- Do not attempt this professional task: Measured handoff for Fronius 306
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Measured handoff for Fronius 306
What they doCompare the event timeline with DC start thresholds, insulation-test state, irradiance and temperature; use those values to decide whether this is expected state or a blocked input.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Preserve the exact event context
Save event 306, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.
Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.
Evidence: Fronius Symo / Eco status diagnostics
Collect one safe discriminator
Read monitoring only. Compare the event start/end with daylight, DC voltage, temperature and whether feed-in resumes without intervention. Record irradiance, DC voltage and whether feed-in resumes when conditions change; do not change multiple parameters or circuits at once.
Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.
Evidence: Fronius Symo / Eco status diagnostics
Respect the electrical stop point
A single documented self-test or cold/start wait can be observed. If the stated condition clears but feed-in does not resume, escalate with the timeline.
Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.
Evidence: Fronius Symo / Eco status diagnostics
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- Solar and energy
- Brand
- Fronius
- Product type
- Solar inverter
Known code variants
- événement Fronius 306
- evento Fronius 306
- Fronius Ereignis 306
- Fronius event 306
- Fronius inverter 306
- Fronius Symo / Eco 306
- Fronius Wechselrichter 306
- inversor Fronius 306
- inverter Fronius 306
- onduleur Fronius 306
What it means
Official meaning: PV output is too low for grid feed-in; this can be a normal low-irradiance state. Decision boundary: capture irradiance, DC voltage and whether feed-in resumes when conditions change. Compare the event timeline with DC start thresholds, insulation-test state, irradiance and temperature; use those values to decide whether this is expected state or a blocked input.
Warnings and stop conditions
- Lowsource verified
Monitoring is safe to read, but the inverter and PV strings remain hazardous. Do not open covers or touch conductors.
Evidence: Fronius Symo / Eco status diagnostics
Symptoms and causes
Probable causes · in order
- What the Fronius event establishesConfirmed
The official Fronius Symo / Eco manual defines event 306: PV output is too low for grid feed-in; this can be a normal low-irradiance state.
Evidence: Fronius Symo / Eco status diagnostics
- The observation that changes the next branchPossible
Capture irradiance, DC voltage and whether feed-in resumes when conditions change. A single documented self-test or cold/start wait can be observed. If the stated condition clears but feed-in does not resume, escalate with the timeline.
Evidence: Fronius Symo / Eco status diagnostics
Virtual technician
Does 306 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
Fronius Symo / Eco status diagnostics
Fronius International GmbH · 2025 · official_doc
Was this entry useful?