311

Fronius inverter event 311

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Wall-mounted solar photovoltaic inverter
AsurnipalCC BY-SA 4.0Image source

Risk level

Critical

Stop using the equipment and contact a professional.

Urgency

Immediate

Quick answer

Fronius defines event 311 as: The polarity of one or more DC strings is reversed. The useful next discriminator is the named DC input, recent string work and recorded polarity state. Preserve the event before any reset.

Safety first

What to do now

  • Preserve the exact event context

    Save event 311, timestamp, inverter model/serial, firmware, red-LED state, affected phase/string, power and weather before clearing anything.

  • Collect one safe discriminator

    Leave feed-in stopped. Record the named input and recent string, connector or module work; do not unplug or reverse any DC connector. Record the named DC input, recent string work and recorded polarity state; do not change multiple parameters or circuits at once.

  • Respect the electrical stop point

    Do not reconnect until a PV installer has measured polarity and voltage on every affected string against the approved design.

What you must never do

  • Do not attempt this professional task: Measured handoff for Fronius 311

What a technician must be able to justify

A technician is coming

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured handoff for Fronius 311

    What they doSafely isolate each affected string, measure polarity and open-circuit voltage at the correct test point, compare with the string schedule and correct the DC termination before reconnecting.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Solar and energy
Brand
Fronius
Product type
Solar inverter

Known code variants

  • événement Fronius 311
  • evento Fronius 311
  • Fronius Ereignis 311
  • Fronius event 311
  • Fronius inverter 311
  • Fronius Symo / Eco 311
  • Fronius Wechselrichter 311
  • inversor Fronius 311
  • inverter Fronius 311
  • onduleur Fronius 311

What it means

Official meaning: The polarity of one or more DC strings is reversed. Decision boundary: capture the named DC input, recent string work and recorded polarity state. Safely isolate each affected string, measure polarity and open-circuit voltage at the correct test point, compare with the string schedule and correct the DC termination before reconnecting.

Warnings and stop conditions

  • Criticalsource verified

    Reversed PV polarity and live DC connectors can cause arc, fire and lethal shock. Do not unplug, probe or reverse a string yourself.