710

Fronius solar inverter status 710: Solar Net signal missing

Verified with sources2 sourcesReviewed Oct 18, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted solar photovoltaic inverter
AsurnipalCC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

Status code 710 on a Fronius Primo or Symo inverter means the Fronius Solar Net keep-alive signal is missing. A warning message appears on the display with the red status LED lit, and in multi-inverter systems with Fail-Safe enabled, secondary inverters switch off.

Safety first

Stop and check this first

  • Do not open the data communication cover or remove plug-in option cards yourself: servicing and card installation inside the inverter must only be performed by qualified personnel after isolating AC and DC power.
  • In multi-inverter systems, never disable Fail-Safe Mode to bypass status 710, because Fail-Safe prevents inadmissible grid feed-in when communication with the primary inverter is lost.

Safe checks you can perform

  • Check the Fronius Solar Net status in the SETUP > DATCOM menu on the inverter display
  • Check whether other inverters in the ring also show status 710 and have switched off
  • Verify whether the Fronius Datamanager responds during daylight hours

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Inspect the 'Fronius Solar Net' LED, RJ45 terminating plugs, and ring power supply
  • Do not attempt this professional task: Run the latest software update on the inverter and Datamanager and verify DATCOM settings

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Inspect the 'Fronius Solar Net' LED, RJ45 terminating plugs, and ring power supply

    What they doA Fronius-trained service engineer inspects the 'Fronius Solar Net' LED in the data communication area (lit steady when power supply is OK, or flashing briefly every 5 seconds on overcurrent > 3 A or undervoltage < 6.5 V), checks that a terminating plug is fitted to every free IN or OUT port, and verifies that only one Fronius Datamanager is installed and located in the last position of the ring line.

    They must show youthe 'Fronius Solar Net' LED status and the terminating plugs fitted to the free IN and OUT connections.

    In writingthe Solar Net ring test results, any cables or terminating plugs replaced, and whether an external DATCOM power supply was needed.

  2. Run the latest software update on the inverter and Datamanager and verify DATCOM settings

    What they doThe technician runs the latest software update for both the inverter and the Fronius Datamanager (the second remedy in the Class 7 table for code 710), verifies that each inverter has a unique address (00-99) and Protocol type set to Fronius Solar Net under SETUP > DATCOM, and checks the Fail-Safe settings.

    They must show youthe updated software versions on the inverter and Datamanager and an active status in SETUP > DATCOM.

    In writingthe firmware versions installed, the unique DATCOM inverter numbers assigned, and confirmation that status 710 has cleared.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Check the Fronius Solar Net status in the SETUP > DATCOM menu on the inverter display

    No special tools

    Who:
    you, using the keypad on the Fronius Primo display.
    How:
    press any key to activate display backlighting, press the Menu key to open the menu level, select SETUP > DATCOM, and read the Status, Inverter number, and Protocol type items.
    Result that matters:
    checking the Solar Net status at the inverter as recommended first in the Class 7 status code table.
    If the Status entry reports a data communications error:
    write down the inverter number and protocol type shown to share with your technician.
    If communication shows active again and status 710 clears:
    monitor the display to see whether the warning returns.
    Evidence to keep:
    a photo of the inverter display showing status 710 and the SETUP > DATCOM screens.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

  2. Check whether other inverters in the ring also show status 710 and have switched off

    No special tools

    Who:
    you, reading the external displays of the inverters.
    How:
    if your installation links several inverters in a Fronius Solar Net ring (one primary unit with Datamanager and secondary Lite units), check each inverter display from the outside without opening any covers.
    Result that matters:
    determining whether the Fail-Safe function has switched off the secondary inverters due to a ring break or Datamanager outage.
    If all secondary inverters have switched off with status 710:
    the Solar Net connection is interrupted or the primary Datamanager has stopped sending its signal.
    If only a single inverter shows status 710:
    the communication issue is isolated to that unit's link or DATCOM setting.
    Evidence to keep:
    a list of which inverters in the ring show status 710 and which remain operating.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

  3. Verify whether the Fronius Datamanager responds during daylight hours

    No special tools

    Who:
    you, while sufficient daylight and DC voltage are available.
    How:
    check whether the Fronius Datamanager 2.0 is reachable in Fronius Solar.web during the day (when Night mode is set to OFF, DATCOM does not run at night) and note whether status 710 remains on the display continuously.
    Result that matters:
    distinguishing normal nighttime DATCOM shutdown from a persistent daytime Solar Net fault.
    If status code 710 is displayed all the time during daylight operation:
    notify a Fronius-trained service engineer as instructed by the manual.
    If communication was only unavailable overnight with Night mode set to OFF:
    that nighttime behavior is normal and does not indicate a fault.
    Evidence to keep:
    the time when status 710 appeared and whether Solar.web updates during daylight.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Solar and energy
Brand
Fronius
Product type
Solar inverter

Known code variants

  • Estado 710
  • Fronius 710
  • Fronius codigo 710
  • Fronius Primo error 710
  • Fronius status code 710
  • Solar Net falta el mensaje de entrada
  • Solar Net Keep alive signal missing
  • Status 710

What it means

In the Fronius Primo operating instructions (document 42,0410,2165, version 030-15102024), Class 7 status code 710 ('Solar Net - Keep alive signal missing') indicates that the inverter is no longer receiving the keep-alive signal over the Fronius Solar Net ring. A warning message appears on the display with the general status LED lit red. In multi-inverter rings with Fail-Safe enabled (Fail-Safe Mode set to Permanent and Fail-Safe Behaviour set to Disconnect), the primary inverter with Datamanager sends a signal to secondary (Lite) units; if the Datamanager fails or the Solar Net connection breaks, all units switch off with status 710. A code alone never proves a part is faulty.

Warnings and stop conditions

  • Highsource verified

    Do not open the data communication cover or remove plug-in option cards yourself: servicing and card installation inside the inverter must only be performed by qualified personnel after isolating AC and DC power.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

  • Mediumsource verified

    In multi-inverter systems, never disable Fail-Safe Mode to bypass status 710, because Fail-Safe prevents inadmissible grid feed-in when communication with the primary inverter is lost.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

Symptoms and causes

Probable causes · in order

  • Interrupted Fronius Solar Net ring cable or missing RJ45 terminating plugCommon

    The data communication cable between the IN and OUT Fronius Solar Net ports of the linked DATCOM components is interrupted or damaged, or a required terminating plug is missing on a free IN or OUT connection.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

  • Fronius Solar Net power supply fault (overcurrent or undervoltage) or Datamanager failurePossible

    The Fronius Solar Net ring experiences overcurrent (current flow > 3 A, e.g. from a short circuit in the ring) or undervoltage (< 6.5 V when too many DATCOM components lack an additional power supply), or the primary Fronius Datamanager has failed.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

  • Incorrect DATCOM address/protocol setting or outdated inverter and Datamanager softwareLess common

    The inverter number (00-99) or protocol type (Solar Net vs. Interface) under SETUP > DATCOM is misconfigured, more than one Fronius Datamanager is installed in the same Solar Net ring, or the inverter and Datamanager software needs updating.

    Evidence: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

Virtual technician

Does 710 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.

Sources and technical references

  1. 1

    Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165)

    Fronius International GmbH · 2024 · official_doc

  2. 2

    Fronius Primo 3.0-1 - 8.2-1 Manual de instrucciones (42,0410,2165)

    Fronius International GmbH · 2024 · official_doc

Sources: Fronius Primo 3.0-1 - 8.2-1 Operating Instructions (42,0410,2165) · Fronius Primo 3.0-1 - 8.2-1 Manual de instrucciones (42,0410,2165)reviewed 2026-10-18 · verified

Was this entry useful?