Huawei inverter 2013: one or more PV strings report abnormal power

Verified with sources1 sourceReviewed Aug 23, 2026
Technician coming? See what they must show you
Wall-mounted solar photovoltaic inverter
AsurnipalCC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

High

Quick answer

Huawei alarm 2013 means one or more PV strings report abnormal power. The deciding evidence is the affected string’s current/power trace versus a neighbouring string during the same unshaded interval. This is an installer-grade electrical alarm: do not infer or buy a component from the ID alone.

Safety first

Stop and check this first

  • Monitoring data is safe to read, but PV connectors and strings may carry lethal DC voltage. Do not unplug or test them to create a comparison.

Safe checks you can perform

  • Preserve the exact alarm context
  • Collect the safe discriminator
  • Respect the electrical stop boundary

Leave these tasks to a qualified professional

  • Do not attempt this professional task: Measured installer handoff for 2013

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. Measured installer handoff for 2013

    What they doUse the monitoring comparison to select one string, then measure current/voltage and inspect shading, module mismatch, connectors and cable losses before replacing hardware.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Preserve the exact alarm context

    No special tools

    Save a screenshot of 2013 with timestamp, cause ID, inverter model/serial, firmware, operating power, affected string/MPPT/phase and weather. Do not clear the alarm first.

    Monitoring data is safe to read, but PV connectors and strings may carry lethal DC voltage. Do not unplug or test them to create a comparison.

    Evidence: Huawei Inverter Alarm Reference

  2. Collect the safe discriminator

    No special tools

    Use FusionSolar only to compare the named string with neighbouring strings during the same unshaded interval. Do not unplug strings or open the inverter. Record the affected string’s current/power trace versus a neighbouring string during the same unshaded interval; do not change several settings or circuits at once.

    Monitoring data is safe to read, but PV connectors and strings may carry lethal DC voltage. Do not unplug or test them to create a comparison.

    Evidence: Huawei Inverter Alarm Reference

  3. Respect the electrical stop boundary

    No special tools

    A difference isolated to one string narrows the visit; a shared drop changes the branch. Neither result identifies a module or inverter board by itself.

    Monitoring data is safe to read, but PV connectors and strings may carry lethal DC voltage. Do not unplug or test them to create a comparison.

    Evidence: Huawei Inverter Alarm Reference

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
Solar and energy
Brand
Huawei
Product type
Solar inverter

Known code variants

  • alarma Huawei 2013
  • alarme Huawei 2013
  • allarme Huawei 2013
  • erreur SUN2000 2013
  • error SUN2000 2013
  • errore SUN2000 2013
  • Huawei alarm 2013
  • Huawei inverter 2013
  • Huawei Wechselrichter 2013
  • inversor Huawei 2013
  • inverter Huawei 2013
  • onduleur Huawei 2013
  • SUN2000 error 2013
  • SUN2000 Fehler 2013

What it means

Huawei’s official inverter alarm reference defines 2013 as a condition in which one or more PV strings report abnormal power. It reports a controller/protection state, not a universal failed part. Record the affected string’s current/power trace versus a neighbouring string during the same unshaded interval. The next proof is measured: Use the monitoring comparison to select one string, then measure current/voltage and inspect shading, module mismatch, connectors and cable losses before replacing hardware.

Warnings and stop conditions

  • Mediumsource verified

    Monitoring data is safe to read, but PV connectors and strings may carry lethal DC voltage. Do not unplug or test them to create a comparison.

    Evidence: Huawei Inverter Alarm Reference

Symptoms and causes

Probable causes · in order

  • What Huawei alarm ID establishesConfirmed

    Huawei documents 2013 as an alarm in which one or more PV strings report abnormal power. Confirm the exact inverter model, firmware, cause ID and affected string/phase because applicability and handling can differ by product family.

    Evidence: Huawei Inverter Alarm Reference

  • The observation that selects the next branchPossible

    Decision evidence: the affected string’s current/power trace versus a neighbouring string during the same unshaded interval. A difference isolated to one string narrows the visit; a shared drop changes the branch. Neither result identifies a module or inverter board by itself.

    Evidence: Huawei Inverter Alarm Reference

Virtual technician

Does 2013 still appear after these checks?