Vaillant

Independent technical reference

Vaillant

47 published entries

ErrorBase is not affiliated with Vaillant. The logo and colour only help you recognise the brand. Technical information separated from official support routes.

Documented codes

Air-to-water heat pump 4

Tankless gas water heater 5

Gas boiler 38

F20Vaillant boiler F20: safety temperature limiter detected excessive flow or return temperatureHigh· BoilersF22Vaillant boiler F22: too little heating water or system pressureHigh· BoilersF23Vaillant boiler F23: flow and return temperature difference is too largeHigh· BoilersF24Vaillant boiler F24: flow temperature is rising faster than the safe gradientHigh· BoilersF25Vaillant F.25 on a gas boiler: flue gas temperature too highHigh· BoilersF26Vaillant F.26 on a gas boiler: gas valve not workingHigh· BoilersF27Vaillant boiler F27: a flame signal exists while the gas valve should be closedHigh· BoilersF28Vaillant boiler F28: no valid flame was detected during ignitionHigh· BoilersF29Vaillant boiler F29: the operating flame was lost and reignition failedHigh· BoilersF32Vaillant F.32 on a gas boiler: fan faultHigh· BoilersF35Vaillant F35 on a gas boiler: air and flue duct faultHigh· BoilersF42Vaillant F42 on a gas boiler: gas coding resistor faultHigh· BoilersF54Vaillant F54 fault: insufficient gas supply at boiler startHigh· BoilersF55Vaillant F55 on a gas boiler: carbon monoxide sensor faultHigh· BoilersF56Vaillant F56 on a gas boiler: carbon monoxide limit exceededHigh· BoilersF57Vaillant F57 boiler fault: comfort mode combustion errorHigh· BoilersF61Vaillant boiler F61: gas-valve control did not operate in its required timingHigh· BoilersF62Vaillant boiler F62: flame switch-off was detected after the allowed delayHigh· BoilersF64Vaillant F.64 on a gas boiler: electronics or sensor faultHigh· BoilersF67Vaillant F.67 on a gas boiler: implausible flame signalHigh· BoilersF68Vaillant F.68 on a gas boiler: unstable flame signalHigh· BoilersF70Vaillant boiler F70: appliance coding does not match the installed control hardwareHigh· BoilersF72Vaillant boiler F72: flow and return sensors report an implausible differenceHigh· BoilersF75Vaillant boiler F75: the pressure sensor did not detect the expected change when the pump startedHigh· BoilersF77Vaillant F.77 on a gas boiler: flue flap or condensate pumpHigh· BoilersF83Vaillant F83 fault: too little temperature rise after burner startHigh· BoilersF00Vaillant F.00 on an ecoTEC boiler: flow sensor interruptionMedium· BoilersF01Vaillant F.01 on a gas boiler: return sensor interruptionMedium· BoilersF10Vaillant F.10 on a gas boiler: flow sensor short circuitMedium· BoilersF11Vaillant F.11 on a gas boiler: return sensor short circuitMedium· BoilersF13Vaillant F13 boiler fault: hot water cylinder sensor shortMedium· BoilersF49Vaillant F.49 on a gas boiler: undervoltage on the eBUSMedium· BoilersF65Vaillant F.65 on a gas boiler: electronics running too hotMedium· BoilersF73Vaillant F.73 on a gas boiler: water pressure sensor signal too lowMedium· BoilersF74Vaillant F.74 on a gas boiler: water pressure too highMedium· BoilersF81Vaillant F81 on a gas boiler: cylinder charging incompleteMedium· BoilersF82Vaillant F82 on a gas boiler: powered anode circuit faultMedium· BoilersF84Vaillant F.84 on a gas boiler: implausible flow return differenceMedium· Boilers