ABB Terra AC 0x0002 on an EV charger: residual current detected

Risk level
High
Professional inspection is recommended.
Urgency
High
Quick answer
The Terra AC detected residual current (30 mA AC or 6 mA DC) leaking to earth in the charge circuit. Switch it off at its breaker, wait at least 1 minute and call an electrician.
Safety first
Stop and check this first
- Do not charge again with 0x0002 active. ABB says to de-energise the unit and contact the manufacturer or a qualified electrical contractor.
Safe checks you can perform
- De-energise the Terra AC
- Exact code and manual version
- Insulation measurement and RCD test
Leave these tasks to a qualified professional
- Do not attempt this professional task: Circuit insulation resistance
- Do not attempt this professional task: RCD trip test
- Do not attempt this professional task: Earth continuity
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Circuit insulation resistance
What they doThe electrician measures Terra AC circuit insulation with an installation tester, with the unit isolated.
They must show youthe reading against the minimum in your wiring rules.
In writingvalue, test voltage and conclusion.
RCD trip test
What they doTests the upstream RCD or RCBO with an RCD tester.
They must show youthe measured trip time.
In writingdevice type, test current and result.
Earth continuity
What they doMeasures protective conductor continuity to the charger.
They must show youthe continuity reading.
In writingvalue against the permitted value and where it was measured.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
De-energise the Terra AC
- Who:
- you, only operating the consumer unit switch.
- How:
- open the breaker feeding the Terra AC and wait at least 1 minute, as ABB says.
- Result that matters:
- the charger is dead while it is checked.
- If the LED goes out with that breaker:
- the circuit is correctly identified.
- If you do not know which one it is:
- do not try at random; wait for the electrician.
- Evidence to keep:
- photo of the breaker and of the code in the app before switching off.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Exact code and manual version
- Who:
- you, no tools.
- How:
- note the code shown in the app and the product label, and compare it with the table in your unit's manual.
- Result that matters:
- 0x0002 means residual current for your version.
- If it matches:
- follow the residual current procedure.
- If your manual gives another meaning:
- follow your manual and tell the technician.
- Evidence to keep:
- screenshot of the code and photo of the label.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Insulation measurement and RCD test
- Who:
- qualified electrician.
- How:
- measure insulation resistance on the charger circuit and test the RCD protecting it.
- Result that matters:
- whether the leak is in the fixed installation.
- If insulation is low:
- confirms a leak in the fixed circuit.
- If everything is correct:
- points to the vehicle or the cable.
- Evidence to keep:
- report with readings.
Measuring insulation and testing RCDs is electrician work. You do not open the charger.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- EV charging
- Brand
- ABB
- Product type
- EV charger
Known code variants
- ABB Terra AC 0x0002
- ABB Terra AC error 0x0002 corriente residual
- ABB Terra AC Residual current detected
- Terra AC error 0x0002
- Terra AC Residual current detected
What it means
In the Terra AC user manual (revision 004), 0x0002 is Residual current detected: there is residual current of 30 mA AC or 6 mA DC in the charge circuit and current leaks to ground. The error LED comes on and the app shows the code. The leak can be in the vehicle, the cable or the charger itself. ABB says to de-energise the unit and contact the manufacturer or an electrician. The code table depends on the manual edition: the 2020 Spanish installation manual assigns different meanings to some hexadecimal codes. Always compare with the manual for your unit.
Warnings and stop conditions
- Highsource verified
Do not charge again with 0x0002 active. ABB says to de-energise the unit and contact the manufacturer or a qualified electrical contractor.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Symptoms and causes
Probable causes · in order
- Leak in the vehicle or charging cablePossible
If behaviour changes with another car or on another charger, the origin points to the vehicle side. Professional diagnosis confirms it.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
- Leak in the charger circuitPossible
If the code appears with no other vehicle to explain it, the electrician measures insulation on the Terra AC circuit.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Virtual technician
Does 0x0002 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
ABB E-mobility · 2023 · manual