- EV charging
- EV charger
0x0010
ABB Terra AC 0x0010 on an EV charger: input voltage not sufficient

Risk level
Medium
Proceed carefully and stop if the check is unclear.
Urgency
Medium
Quick answer
The Terra AC measures insufficient voltage at its power input (Under voltage). ABB says to contact the manufacturer or a qualified electrical contractor to check the supply.
Safety first
Stop and check this first
- ABB refers this code to the manufacturer or a qualified electrical contractor. Do not open the charger or the consumer unit to measure yourself.
Safe checks you can perform
- Exact code and when it appears
- Voltage measurement at origin and charger
- Circuit connection inspection
Leave these tasks to a qualified professional
- Do not attempt this professional task: Voltage with and without load
- Do not attempt this professional task: Circuit connections and insulation
What a technician must be able to justify
Technician visit
These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.
These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.
Voltage with and without load
What they doThe electrician measures voltage at the origin and at the Terra AC with no load and during a charge.
They must show youreadings at both points.
In writingvalues against nominal voltage and the conclusion.
Circuit connections and insulation
What they doChecks circuit terminal tightness and measures insulation resistance with the unit isolated.
They must show youany point corrected and the insulation reading.
In writingconnections checked and values against wiring rules.
Before accepting a part or repair
Nothing has been shown yet. Do not accept a part swap based on the code alone.
Follow these steps
Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.
Exact code and when it appears
- Who:
- you, no tools.
- How:
- note the app code, the time and whether it matches other heavy loads in the home, and confirm it in your unit's manual.
- Result that matters:
- whether undervoltage depends on time or internal load.
- If it matches heavy loads:
- points to the internal installation.
- If it appears at times unrelated to your use:
- points to the network.
- Evidence to keep:
- screenshots of the code with date and time.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Voltage measurement at origin and charger
- Who:
- qualified electrician.
- How:
- measure voltage at the main consumer unit and at the Terra AC input, with no load and while charging.
- Result that matters:
- where the voltage drops.
- If it is already low at the consumer unit:
- confirms a network problem.
- If it only drops at the charger:
- confirms a circuit problem.
- Evidence to keep:
- report with readings.
Measuring mains voltage is electrician work.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Circuit connection inspection
- Who:
- qualified electrician.
- How:
- with the circuit isolated, check tightness of connections at the consumer unit and the charger input.
- Result that matters:
- secure connections with no heat marks.
- If a connection is loose or marked:
- confirms a voltage drop cause.
- If they are fine:
- the focus goes back to the network or the circuit size.
- Evidence to keep:
- photos of the connections checked.
Opening the consumer unit or the charger is electrician work.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Still not solved
If the error persists, stop here. See what the technician must do and show you.
Where this code applies
A code is meaningful only inside the right product and version context.
Primary scope
- System
- EV charging
- Brand
- ABB
- Product type
- EV charger
Known code variants
- ABB Terra AC 0x0010
- ABB Terra AC error 0x0010 subtensión
- ABB Terra AC Under voltage
- Terra AC error 0x0010
- Terra AC Under voltage
What it means
In the Terra AC user manual (revision 004), 0x0010 is Under voltage: the voltage on the power input is not sufficient. The charger shows it with the error LED and the code in the app. The drop can come from the network, the service connection or the circuit feeding the charger, and the code does not say where. The code table depends on the manual edition: the 2020 Spanish installation manual assigns different meanings to some hexadecimal codes. Always compare with the manual for your unit.
Warnings and stop conditions
- Mediumsource verified
ABB refers this code to the manufacturer or a qualified electrical contractor. Do not open the charger or the consumer unit to measure yourself.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Symptoms and causes
Probable causes · in order
- Low network voltagePossible
If voltage already arrives low at the main consumer unit, the origin is outside the home and the network operator resolves it.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
- Voltage drop on the charger circuitPossible
If voltage is correct at the consumer unit but low at the charger while charging, it points to a loose connection or undersized circuit.
Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
Virtual technician
Does 0x0010 still appear after these checks?
Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.
Sources and technical references
- 1
User manual Terra AC (BCM.V3Y00.0-EN, revision 004)
ABB E-mobility · 2023 · manual
Was this entry useful?