0x0080

ABB Terra AC 0x0080 on EV charger: internal overtemperature

Verified with sources2 sourcesReviewed Oct 18, 2026
Technician coming? See the 2 steps they must show you
Wall-mounted EV charger (wallbox) with charging cable
Solomon203CC BY-SA 4.0Image source

Risk level

Medium

Proceed carefully and stop if the check is unclear.

Urgency

Medium

Quick answer

On the ABB Terra AC wallbox, error code 0x0080 ('Over temperature') means the internal temperature is too high. Check the operating temperature rating on the product label and look for direct sunlight or blocked airflow; if the issue persists, stop using the EVSE and call an electrician.

Safety first

Stop and check this first

  • ABB's hot-surface warning symbol highlights the risk of burn injuries, and the manual instructs not to use the EVSE if over-temperature cannot be solved: never open the cabinet yourself.

Safe checks you can perform

  • Check the operating temperature on the label and let the unit cool
  • Make sure the > 200 mm clearance around the EVSE is unobstructed
  • Stop using the EVSE and open the supply breaker if 0x0080 persists

Leave these tasks to a qualified professional

  • Do not attempt this professional task: AC input voltage measurement and terminal block inspection
  • Do not attempt this professional task: Relocation assessment or ABB service escalation

What a technician must be able to justify

Technician visit

These are the steps they must carry out and show you. Tick them as they work: if steps are skipped, do not accept a part swap.

These are not instructions for opening or handling the equipment yourself. They are the checks that should support a technical conclusion.

  1. AC input voltage measurement and terminal block inspection

    What they doAfter opening the breaker and waiting at least 1 minute, a qualified electrical contractor checks AC input voltage (230 V AC nominal, max 264 V single-phase; 400 V AC nominal, max 460 V three-phase) and inspects input and output terminal blocks at 1.2 Nm torque.

    They must show youthe measured AC input voltage and the condition of the AC input and EV cable terminal blocks.

    In writingthe phase and neutral voltage readings, confirmation of 1.2 Nm terminal torque and whether any terminal showed heat marks.

  2. Relocation assessment or ABB service escalation

    What they doThe installer evaluates whether the Terra AC must be moved to a cooler, shaded environment or, if ambient temperature and wiring are within specification, escalates the unit to the local ABB representative.

    They must show youthe ambient temperature reading at the mounting spot and the ChargerSync fault log.

    In writingthe shading or relocation plan, or the ABB service case reference if an internal temperature sensor or board fault is suspected.

Before accepting a part or repair

Nothing has been shown yet. Do not accept a part swap based on the code alone.

Follow these steps

Note: Follow the documented order. An error code identifies the affected system, but it does not prove by itself which part has failed.

  1. Check the operating temperature on the label and let the unit cool

    No special tools

    Who:
    you, inspecting the outside of the Terra AC without opening it.
    How:
    stop the charging session, read the operating temperature specification on the exterior product label and check whether hot weather or direct sun is heating the cabinet.
    Result that matters:
    following ABB's first troubleshooting step for 0x0080 and allowing internal heat to dissipate.
    If it was in direct sun or high heat and clears once cool:
    shade the unit or schedule charging during cooler hours.
    If 0x0080 appears in mild or cool ambient conditions:
    stop using the EVSE and arrange an electrician check.
    Evidence to keep:
    a photo of the product label and a note of the outdoor temperature and time when 0x0080 occurred.

    Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004) · Manual de instalación Terra AC (BCM.V3Y01.0-ES, revisión 001)

  2. Make sure the > 200 mm clearance around the EVSE is unobstructed

    No special tools

    Who:
    you, looking at the area around the charger.
    How:
    check that no storage items, covers or snow are blocking the sides, top or bottom of the Terra AC within the > 200 mm clearance zone specified in section 7.6.3.
    Result that matters:
    removing external airflow obstructions that prevent the enclosure from cooling.
    If clearing objects around the wallbox stops the code returning:
    keep that clearance zone permanently clear.
    If the space around the unit is already open and 0x0080 returns:
    proceed to switch off the breaker.
    Evidence to keep:
    a photo showing the mounting location and clearance around the Terra AC.

    Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)

  3. Stop using the EVSE and open the supply breaker if 0x0080 persists

    No special tools

    Who:
    you, at the circuit breaker feeding the charger.
    How:
    if cooling and checking ambient conditions do not solve the problem, obey ABB's instruction not to use the EVSE, open its circuit breaker for at least 1 minute and call a qualified electrical contractor.
    Result that matters:
    preventing further heating while waiting for professional inspection.
    If the breaker is open and the unit is isolated:
    contact your electrical contractor or local ABB representative.
    If you see any heat distortion or cracks on the cabinet or cable:
    report that damage when booking the technician.
    Evidence to keep:
    a screenshot of code 0x0080 in ChargerSync and the time the breaker was opened.

    Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004) · Manual de instalación Terra AC (BCM.V3Y01.0-ES, revisión 001)

Still not solved

If the error persists, stop here. See what the technician must do and show you.

Where this code applies

A code is meaningful only inside the right product and version context.

Primary scope

System
EV charging
Brand
ABB
Product type
EV charger

Known code variants

  • ABB Terra AC 0x0080
  • ABB Terra AC 0x0116 sobrecalentamiento
  • ABB Terra AC Over temperature
  • ABB wallbox overheating 0x0080
  • cargador ABB Terra AC temperatura interna alta
  • Terra AC 0x0080 internal temperature too high
  • Terra AC error 0x0080
  • Terra AC error 0x0080 sobretemperatura

What it means

In the Terra AC User Manual (BCM.V3Y00.0-EN, revision 004, sections 6.2 and 6.3), error code 0x0080 means 'Over temperature': the internal temperature of the EVSE is too high. Under high ambient temperatures (-35 °C to +50 °C, or -30 °C to +55 °C on MID models), the EVSE automatically reduces output current, and ABB advises installing it out of direct sunlight with more than 200 mm clearance around it. If the issue persists, ABB instructs not to use the EVSE and to contact a qualified electrician or ABB (listed as 0x0116 in the 2020 manual). Code 0x0080 alone never proves an internal part has failed.

Warnings and stop conditions

  • Mediumsource verified

    ABB's hot-surface warning symbol highlights the risk of burn injuries, and the manual instructs not to use the EVSE if over-temperature cannot be solved: never open the cabinet yourself.

    Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)

Symptoms and causes

Probable causes · in order

  • High ambient temperature or direct sunlight on the enclosureCommon

    ABB instructs checking the operating temperature on the product label first, noting that high ambient heat causes automatic current derating or triggers 0x0080.

    Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004) · Manual de instalación Terra AC (BCM.V3Y01.0-ES, revisión 001)

  • Blocked clearance around the wallbox cabinetPossible

    The user manual requires keeping the space around the equipment (> 200 mm clearance in section 7.6.3) free from objects that trap heat around the enclosure.

    Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004)

  • Excessive AC input voltage, terminal heating or internal faultLess common

    In its overheating troubleshooting steps, ABB directs following the procedure for 'the AC input voltage is too high' (checking supply voltage and wiring connections) or suspecting an internal charger fault.

    Evidence: User manual Terra AC (BCM.V3Y00.0-EN, revision 004) · Manual de instalación Terra AC (BCM.V3Y01.0-ES, revisión 001)

Virtual technician

Does 0x0080 still appear after these checks?

Answer a few questions to narrow down the likely cause and the safest next action. Guidance only - it never replaces a professional.